.....i!i_i_:_ii_i!i!i!i!ii_!!_i!i!i!i!!!!i_i_ilIi!iii_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_!_i_i_i
Before calling for service, review this list, It may save you time and expense This list includes common occurrences that are not
the result of defective workmanship or materials in this appliance
OCCURRENCE SOLUTION
Air conditioner will not operate, Wall plug disconnected. Push plug firmly into wall outlet.
Plug Current Device Tripped. Press the RESET button.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
Control is OFE Turn Control ON and set to desired setting
P1 appears in the display window. Drain water as described in Drainage Section.
Shut off in Heat mode. When the air outlet exceeds 158 °F (70 °C), the automatic heat protection
engages. Romove any blockages and let appliance cool down.
Room Temperature lower than the set temperature (Cool Mode). Reset the temperature.
Room Temperature higher than the set temperature (Heat Mode). Reset the temperature.
Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above
60°F (16°C).
Reset to a lower temperature.
Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to
restart when set in the COOL mode.
Air from unit does not feel cold
enough.
Air conditioner cooling, but room
is too warm = ice forming
on cooling coil behind decorative
front
Outdoor temperature below 60 °F (16 °C). To defrost the coil, set FAN ONLY mode.
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY
mode.
Temperature is set too tow for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then,
set temperature to a higher setting.
Exhaust duct not connected or blocked. See EXHAUSTING HOT AIR Section.
Air conditioner cooling, but room
is too warm - NO ice forming on
cooling coil behind decorative
front.
Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.
Temperature is set too high. Set temperature to a lower setting.
Air directional louvers positioned improperly. Position louvers for better air distribution.
Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in
front of unit.
Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.
Unit recently turned on in hot room. Allow additional time to remove "stored heat" from wails, ceiling,
floor and furniture.
Air conditioner turns on and off
rapidly.
Dirty air filter - air restricted. Clean air filter.
Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils
more frequently.
Noise when unit is cooling.
Room too cold.
Air movement sound. This is normal. If too loud, set to lower FAN setting.
Vibraion from uneven floor. Move or support appliance correctly on even surface.
Set temperature too low. Increase set temperature.
Room Too Hot. Set temperature too high. Lower setting.