ALARMFUNCTIONTABLE
Except during power loss, the alarm indicators illuminate
whenever there is an alarm status.
Display Status Function Response
Cabinet Normal operation None
temperature
setting is
displayed
AIternating"E' Operational error Contact service
and "7", "8" or "9" technician.
every half second
Control panel
beeps every 5
seconds. "Door
Ajar" LED is lit.
Control panel
beeps every 5
seconds. "Hi
Temp" LED is lit.
Door Ajar
Freezer
temperature too
high.
Close door. Press
Alarm Reset
to mute audible
alarm (beep).
Contact service
technician. Press
Alarm Reset
to mute audible
alarm (beep).
Press Alarm
Reset button,
"Power A power failure
Loss" LED is occurred.
illuminated.
Display off. Power failure Reconnect power
supply.