ENG
18
If any electrical components need to be replaced, use only the
appropriate components in the spare part list supplied by the
technical service department of Frigoglass.
Keep the glass door of the cooler closed during maintenance. If the
compressor needs to be replaced, you may need to use adequate
support to stabilize the cooler.
After maintenance operations make sure that the strain relief, which
supports the supply cord, is assembled properly.
If the ICM is not functioning properly or is out of order, please check the following before calling the
authorised service provider:
FAULT POSSIBLE REASONS HANDLING
The ICM does not
work.
Power cord not plugged in. Plug it in.
No power supply at the socket. Check the outlet fuse.
The ICM does not
cool.
The ICM has recently been reloaded
with warm products. It takes some time
to cool warm products down.
Preferably, reload the ICM before night
closing.
The ICM is loaded in such a way that
the air circulation in the interior is getting
blocked.
Load the ICM according to the
standards you have been provided
with by the company.
The ICM does not
cool.
The door does not seal properly.
Repair the doors for proper closing
(this type of repair should be
performed by an authorised
technician).
Leakage in the cooling system.
Repair the leakage (this type of repair
should be performed by an authorised
technician).
The ICM makes
noise.
Intense metallic noise. Call a Service technician.
Inclined or not even floor.
Level the ICM properly by adjusting its
feet. Placing a spirit level on the top of
the ICM will assist you in leveling it.
There is water on
the floor.
The drainage hole for the condensate
water is blocked.
Unblock the drainage hole.
There is a leakage in the tray. Call a Service technician.
The lights don’t
work.
The lighting or the transformer are out of
order
Call a Service technician.
If after all the above-mentioned checks the problem with your ICM remains, contact the customer
service department of your supplier and provide the following information:
Type of ICM
Serial number of the ICM
Brief description of the problem / observation