FRIULAIR CWE 110 - User Manual

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
7425MTC044_ManTec_CWE_Rev03_DE_EN.doc
CWE/HWE
Wasserkühler und Wärmepumpe
Water chillers and heat pumps
Luftgekühlte Wasserkühler und Wärmepumpe
Kühlleistung von 13 bis 141 kW, Scrollkompressoren
Kühlmittel R410A
Air cooled water chillers - Air to water heat pumps
Cooling capacity from 13 to 141 kW, scroll compressors
R410A refrigerant

Other manuals for FRIULAIR CWE 110

Questions and Answers

  • R
    rbrennanAug 19, 2025
    Why won't the compressor start in my FRIULAIR Chiller?
    • A
      Alexandra CastanedaAug 19, 2025
      If the compressor in your FRIULAIR Chiller isn't starting, here are a few things to check: * If the thermal protection inside the compressor activated, wait for it to cool down and ensure the compressor is working under normal conditions. Also, check for insufficient refrigerant. * Examine the compressor contactor. Verify the voltage at the coil and the coil's continuity. * If the phase-sequence relay intervened, reverse the two phases upstream from the unit's electrical panel cut-off switch. * If the magnetothermic protection of the compressors opened, look for short circuits in the motor windings. Check for over-absorption of current due to low voltage, and verify the power supply voltage and operating conditions.
  • E
    Eric McdowellNov 8, 2025
    What to do if my FRIULAIR Chiller unit does not start?
    • R
      Regina SilvaNov 8, 2025
      If your FRIULAIR Chiller unit doesn't start, consider these potential causes and solutions: * Ensure the contacts of the main differential switch and the unit's electrical panel cut-off switch are closed. * Verify the I/O/REM switch is in the 'I' position. * Check the pump's functionality and vent the plumbings if there's no consent from the water differential switch. * Wait 3 minutes if the compressor timer is active. * Apply a thermal load or lower the set point if there's no consent from the service thermostat. * Reset the water temperature to be compatible with the anti-freeze thermostat calibration if there's no consent from it. * Inspect and replace defective service, anti-freeze, or entering water temperature probes. * Investigate for current dispersion inside the m...
  • R
    Rachel ClarkNov 27, 2025
    How to fix a FRIULAIR CWE 110 that won't start?
    • G
      Gregory PorterNov 27, 2025
      If your FRIULAIR Chiller isn't starting, the issue could stem from several causes. Begin by ensuring that the contacts of both the main differential switch and the unit's electrical panel cut-off switch are closed. Next, check that the I/O/REM switch is set to the 'I' position. If these aren't the problem, verify the pump is working correctly and vent the plumbings to address potential issues with the water differential switch. Also, allow three minutes for the compressor timer to complete its cycle. If the issue persists, check the service and anti-freeze thermostats, adjusting the thermal load or set point as needed. Finally, inspect the service, anti-freeze, and entering water temperature probes for any defects, and replace them if necessary. If the main differential switch intervened, ...

Summary

The CWE;HWE Series: Overview

Refrigerant gas

Compressors

Details the hermetic scroll compressors used in the series.

Fans

Evaporator

Describes the stainless steel brazed plate evaporator.

Refrigerant circuit

Safety and control devices

Control panel

Describes the control panel's compliance, features, and ON/OFF switch.

Microprocessor controller

Controls and testing

Technical data CWE

Technical data HWE

Performance data CWE

Performance data HWE

Water available pressure and evaporator pressure drop

Working limits

Installation clearance

FRIULAIR CWE 110 Specifications

General IconGeneral
BrandFRIULAIR
ModelCWE 110
CategoryChiller
LanguageEnglish

Related product manuals