Edition 2003 B0310003 5
Technical Specifications
Technical documentation lt. Agreement between the Austrian Federal Regions as per Art. 15b B-
VG on protective measures with regard to small boiler systems or energy conservation
Boiler Type:
Waste-wood Boiler, Turbomat
Manufacturer: FRÖLING Heizkessel- und Behälterbau Ges.mb.H.
Industriestrasse 12, 4710 Grieskirchen
Data 150 220
Measured Quantity Unit Boiler Size
Rated heating efficiency kW 150 200
Heating efficiency range kW 50-150
Fuel-heating efficiency at rated
heating efficiency kW 164.8
Permitted fuel See page 4
Fuel through-put at rated
heating efficiency kg/h 50 67
Flue gas temperature °C 190 190
Flue gas mass flow at G 50 m³/h 664 885
Necessary draught requirement Pa 20 20
Flue gas pipe diameter mm 200 250
Permitted operating pressure bar 3 3
Permitted operating temperature °C 95 95
Testing Institute TÜV
Test report no.
Exhibition Date 01.08.2003
Carbon monoxide (CO) mg/MJ 39
Nitrous oxide (NOx) mg/MJ 91
Organ. Hydrocarbons (OGC) mg/MJ 2
Dust mg/MJ 18
Boiler Efficiency Rating % 91.0
Store Required Recommended