EasyManua.ls Logo

Frost-Tech S096-125 - Storage Temperature Too High; Storage Temperature Too Low; Cabinet Lighting Failed

Default Icon
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Storage temperature is too high
Possible cause Corrective Measure
A) Automatic defrosting active
B) Ambient temperature is too
high or thermostat
misadjusted
C) Distance to wall not
adhered to
D) Lack of air intake due to
obstruction of grill
E) Condenser fins dirty
Not required, temporary minor
temperature rise during defrosting
is normal
Avoid extreme operating
environment. Adjust storage
temperature
Maintain prescribed minimum
distance
Remove any obstacles in the air
intake area
Perform maintenance
3. Storage temperature is too low
Possible Cause Corrective Measure
A) Maladjustment
Adjust storage temperature in small increments
4. Cabinet lighting failed partly or completely
Possible Cause Corrective Measure
A) Lighting not switched on
B) The light fitting or the starter is
defective
Switch lighting on
Replace light or
starter