3000 OCF Gas Fryer Heating Failure Instructions
For software version 0551
Page 4 of 4
2. Press the (right) arrow key two times until Tech Mode is displayed. Press the
(check) key.
3. Enter code 7628.
4. Follow the sequence below to configure the controller.
Left Display Right Display Action
Locale Non-ce
Press  to scroll to choice CE, CE Belgium or
Non-CE and press . NOTE: CE should only
be selected for countries in the European
Common Union or those that follow the EU
standards.
SYSTEM TYPE OCF
Press .
***NOTE: Do not change this setting.***
ENERGY GAS
Press  to choose Gas or Electric. Press .
type GL30 FULL
Press  to choose model and vat type. Press .
FRESH OIL NONE
Press  to choose JIB, Bulk or None. Press .
WASTE NONE
Press  to choose JIB, Bulk or None. Press .
RESET
PRODUCTS
NO
With
NO displayed press .
NOTE: Change this with caution. If yes is
chosen, all hand/factory programmed menus
will be erased and overwritten.
This option is not displayed unless the
system type is changed.
Exit Exit
Press button once to return exit to OFF.
Repeat the above procedures for each controller.
Cycle the control power using the hidden reset
momentary rocker switch under the left control
box. HOLD THE SWITCH FOR 15 SECONDS
ENSURING THE MIB BOARD HAS POWERED
FULLY DOWN (see Figure 3).
*** Once all the fryer boards
have rebooted it is
necessary to take the
handwritten recorded settings and enter them
back into in the controllers for proper function
of the fryer.
Figure 3

Other manuals for Frymaster 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Frymaster 3000 and is the answer not in the manual?

Frymaster 3000 Specifications

General IconGeneral
BrandFrymaster
Model3000
CategoryController
LanguageEnglish