3.5/28rnm
LENS
ST8O1

Other manuals for FUJICA ST801

Question and Answer IconNeed help?

Do you have a question about the FUJICA ST801 and is the answer not in the manual?

Summary

Disassembly

Mount Ring

Instructions for removing the mount ring assembly.

Aperture Disassembly

Steps for disassembling aperture components.

Helicoid Disassembly

Steps for disassembling helicoid components.

Repair and Adjustment

Focusing Adjustment

Procedure for adjusting lens focusing.

Helicoid Repair

Steps to repair helicoid movement issues.

Aperture Adjustment

Procedure for adjusting aperture settings.

Repairing Aperture Blades Jammed with Oil

Steps to fix aperture blades stuck due to oil.

Repairing Aperture Seat

Steps to fix issues with the aperture seat.

Repairing Mount Ring Levers

Procedure to fix issues with mount ring levers.

Aperture Selector Ring

Instructions for handling the aperture selector ring.

Cam Ring Operation

Steps to fix issues with the cam ring.

Aperture Transmission Pin Check

Checking the aperture transmission pin for height and damage.

Inspection Procedures

Appearance Inspection

Checking for scratches, dirt, or contamination.

Helicoid Operation Check

Verifying smooth movement of the helicoid.

Aperture Operation Check

Checking aperture ring and blades for proper function.

Setting After Inspection

Setting focusing ring and aperture to default positions.

Parts List

Repair Tools

FUJICA ST801 Specifications

General IconGeneral
Film Format35mm
Lens MountM42 screw mount
Exposure MeteringTTL center-weighted
Year Introduced1972
TypeSLR
ShutterFocal plane shutter
Shutter Speed1 sec to 1/2000 sec, B
FlashHot shoe
ManufacturerFuji
Power SourcePX625 mercury battery
ViewfinderFixed pentaprism

Related product manuals