Do you have a question about the FujiFilm FDR ES DR-ID1270 and is the answer not in the manual?
Scintillator | CsI (Cesium Iodide) |
---|---|
Pixel Pitch | 150 μm |
Pixel Size | 150 μm |
Spatial Resolution | 3.3 lp/mm |
A/D Conversion | 16-bit |
Compatible Examinations | General Radiography |
Data Output | DICOM 3.0 |
Interface | Gigabit Ethernet |
Power Supply | AC 100-240 V, 50/60 Hz |
Detector Type | Indirect Conversion |
Image Size | 17 x 17 inches |
Effective Imaging Area | 43 cm × 43 cm |
Active Area | 43 cm × 43 cm |
Matrix Size | 2816 x 2816 pixels |
Dynamic Range | 14 bits |
Dimensions (W × D × H) | 460 x 460 x 15 mm |
Operating Environment | 10°C to 35°C, 30% to 75% RH |
Storage Environment | -20°C to 60°C, 10% to 90% RH (Non-condensing) |
Type | Digital Radiography System |
Provides comprehensive safety information, including electric shock and explosion warnings, for proper product operation.
Details specific warnings and precautions related to electrical hazards when using the equipment.
Highlights warnings concerning potential explosion hazards and the use of flammable gases near the equipment.
Outlines actions to take in case of product abnormalities such as smoke, strange odors, or damage.
Provides essential precautions for the safe and correct installation of the equipment.
Details critical precautions for safely charging the optional battery pack to prevent damage or hazards.
Provides comprehensive guidelines and warnings for the safe handling, use, and storage of battery packs.
Covers additional warnings and cautions not categorized elsewhere, ensuring overall product safety.
Explains the EMC compliance of the DR-ID1270 according to medical device standards.
Provides specific details on the DR-ID1270's adherence to EMC standards and potential interference.
Details essential precautions to be observed when operating the DR-ID1270 system.
Provides guidance on the correct and safe handling of the flat panel sensor and its components.
Outlines precautions to take before performing an X-ray exposure with the system.
Specifies precautions to follow while an X-ray exposure is in progress.
Details precautions regarding the load applied to the flat panel sensor to prevent damage.
Illustrates the overall system configuration of the DR-ID1270, including components and connections.
Highlights the key features and design aspects of the DR-ID1270 flat panel sensor system.
Specifies the required environmental and installation conditions for the DR-ID1270.
Outlines the technical specifications for the wireless communication capabilities of the DR-ID1270.
Guides users through the essential steps for preparing the flat panel sensor for use.
Guides users on the proper procedure for charging the flat panel sensor's battery pack.
Provides instructions for starting up and shutting down the entire DR-ID1270 system correctly.
Details the step-by-step process for starting the DR-ID1270 system.
Guides users through the proper procedure for shutting down the DR-ID1270 system.
Outlines daily inspection and maintenance tasks that users should perform.
Provides precautions for the proper functioning of the automatic X-ray detection feature.
Lists maintenance and inspection items that must be performed by a specified dealer or representative.