Fresh air control output
Indoor unit type Connector
Compact cassette CN6
Cassette CN6
Slim duct CN6
Duct CN6
Floor/Ceiling
Ceiling
Signal linked to air conditioner indoor fan on can be output.
* However, signal becomes off during cold air prevention control operation.
Circuit diagram example
Locally purchased
Indoor unit
control PCB
Connector
1
12 V
On/Off
2
Signal
Relay
power
supply
Example: Fan
Connected unit
Example:
Relay unit
10 m*
*: Make the distance from the PCB to the connected unit within 10 m.
Relay spec.: Rated DC 12 V, 50 mA to less.
On
Off
Operation
Stop
Indoor fan
Output signal
Optional part
Indoor unit type Part name Model name
Compact cassette Fresh air intake kit
UTZ-VXAA
*
Cassette Fresh air intake kit
UTZ-VXAA
*
Slim duct External control set UTD-ECS5A
Duct External control set UTD-ECS5A
Floor/Ceiling
Ceiling
*: This wire is included in fresh air intake kit (UTZ-VXAA).
- 229 -
6-1. Indoor unit 6. External input and output
SYSTEM
DESIGN
SYSTEM
DESIGN