EasyManua.ls Logo

Fujitsu AGU9RLF - User Manual

Fujitsu AGU9RLF
319 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
AIR CONDITIONER
Multi: 2, 3, 4 rooms type
DESIGN & TECHNICAL MANUAL
INDOOR
AUU7RLF
AUU9RLF
AUU12RLF
AUU18RLF
ARU7RLF
ARU9RLF
ARU12RLF
ARU18RLF ARU24RLF
ASU7RLF1
ASU9RLF1
ASU12RLF1
ASU15RLF1
ASU7RLF*
ASU9RLF*
ASU12RLF*
ASU9RLS2*
ASU12RLS2*
ASU15RLS2*
ASU18RLF
ASU24RLF
AGU9RLF
AGU12RLF
AGU15RLF
*: AOU36RLXFZ1 is not connectable.
OUTDOOR
AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ1
DR_MU008EF_07
2018.06.14

Table of Contents

Other manuals for Fujitsu AGU9RLF

Questions and Answers

  • S
    sparkerAug 13, 2025
    What to do if my Fujitsu AGU9RLF remote is not working due to a communication error?
    • J
      Jason ButlerAug 13, 2025
      If you're experiencing a Wired Remote Controller Communication Error with your Fujitsu Air Conditioner, check the voltage. If it's DC12V, the remote control has failed and should be replaced. If it's DC 0V, the Controller PCB has failed and should be replaced after rechecking the remote control.
  • M
    Maria EdwardsAug 17, 2025
    What to do if my Fujitsu AGU9RLF has a drainage error?
    • J
      Jesse SanchezAug 17, 2025
      If your Fujitsu Air Conditioner is experiencing drainage issues, start by inspecting the float switch for proper operation using a meter to check its on/off switching. If the float switch is defective, replace it. Also, examine the drain hose for any clogs and clear them if necessary. If these steps don't resolve the issue, consider replacing the controller PCB.
  • E
    Eugene KnightAug 20, 2025
    How to fix a Fujitsu AGU9RLF indoor unit fan motor error?
    • E
      Elizabeth WrightAug 20, 2025
      If you're encountering an indoor unit fan motor error with your Fujitsu Air Conditioner, check first the fan and bearing. If either is damaged, replace them. If the motor itself is faulty, replace the indoor unit fan motor. If these steps do not resolve the issue, replace the controller PCB.
  • K
    Keith StarkAug 25, 2025
    What to do if my Fujitsu AGU9RLF shows an indoor room thermistor error?
    • E
      Elizabeth LewisAug 25, 2025
      If your Fujitsu Air Conditioner displays an indoor room thermistor error, begin by checking the connector to ensure it is securely attached and properly connected, and verify that the thermistor cable is not open. If the thermistor is either open or shorted, replace it and then reset the power.
  • D
    Debra JohnsonAug 28, 2025
    How to troubleshoot an Indoor Unit Model Information Error on my Fujitsu Air Conditioner?
    • W
      William CannonAug 28, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Model Information Error, check for external causes such as noise and ensure the ground connection is properly connected. Also, inspect all connectors for looseness or incorrect wiring, and check the PCB for any shorts or corrosion. If the problem persists, consider replacing the Controller PCB.
  • S
    Steven MurphyAug 31, 2025
    What does an Indoor Unit Capacity Error mean on my Fujitsu Air Conditioner?
    • G
      George WilcoxAug 31, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Capacity Error, first verify the total capacity of the connected indoor units. If an abnormal condition is found, correct it by referring to the Installation Manual or Design & Technical Manual. If the problem persists, replace the Main PCB of the Outdoor unit.
  • N
    Nathan KleinSep 4, 2025
    How to fix a Serial Communication Error (Serial Reverse Transfer Error) on a Fujitsu AGU9RLF?
    • M
      Melissa ShepardSep 4, 2025
      If your Fujitsu Air Conditioner displays a Serial Communication Error (Serial Reverse Transfer Error), check all connection lines between the indoor and outdoor units for any looseness or disconnections, referring to the Installation Manual or Data & Technical Manual for correction. Also, check the voltage of the power supply, ensuring it appears at the outdoor unit terminal L1 - L2 within the range of AC187V - 253V. Check that the indicated value swings between AC90V and AC270V at outdoor unit terminal 1 - 3. If the outdoor fan motor, active filter module, or IPM is abnormal, replace the corresponding part. If all parts are normal, replace the Main PCB.
  • D
    Douglas RivasSep 8, 2025
    How to resolve a Damper (Open/Close) simultaneous detection Limit switch error on a Fujitsu AGU9RLF Air Conditioner?
    • C
      Colleen GilbertSep 8, 2025
      If your Fujitsu Air Conditioner displays a Damper(Open/Close) simultaneous detection Limit switch error, replace the limit switch if it is defective. If the problem persists, replace the Controller PCB.

Summary

2. Specifications

2-1. Compact cassette type

Technical specifications for compact cassette indoor units.

2-2. Slim duct type

Technical specifications for slim duct indoor units.

2-3. Wall mounted type

Technical specifications for wall mounted indoor units.

2-4. Floor type

Technical specifications for floor type indoor units.

3. Dimensions

3-1. Compact cassette type

Dimensions and installation space for compact cassette indoor units.

3-2. Slim duct type

Dimensions and installation space for slim duct indoor units.

3-3. Wall mounted type

Dimensions and installation space for wall mounted indoor units.

3-4. Floor type

Dimensions and installation space for floor type indoor units.

4. Wiring diagrams

4-1. Compact cassette type

Wiring diagram for compact cassette indoor units.

4-2. Slim duct type

Wiring diagram for slim duct indoor units.

4-3. Wall mounted type

Wiring diagrams for wall mounted indoor units.

4-4. Floor type

Wiring diagram for floor type indoor units.

6. Fan performance

7. Airflow

8. Noise level curve

8-1. Compact cassette type

Noise level curves for compact cassette indoor units.

8-2. Slim duct type

Noise level curves for slim duct indoor units.

8-3. Wall mounted type

Noise level curves for wall mounted indoor units.

8-4. Floor type

Noise level curves for floor type indoor units.

9. Electrical characteristics

10. Safety devices

11. External input and output

11-1. External input

Details on controlling indoor units via external signals.

11-2. External output

Information on obtaining operation status and error signals externally.

13. Remote controller

13-1. Wireless remote controller (UTY-LNHUM;AR-RAH1 U)

Detailed overview and button functions of UTY-LNHUM/AR-RAH1U remote controller.

13-2. Wireless remote controller (AR-RED1 U;AR-REG1 U)

Detailed overview and button functions of AR-RED1U/AR-REG1U remote controller.

13-3. Wired remote controller (UTY-RNNUM)

Overview, specifications, and installation of the wired remote controller.

13-4. Simple remote controller (UTY-RSNUM: Optional part)

Overview and specifications of the simple remote controller.

14. Function settings

14-1. Indoor unit (setting by jumper wire)

Setting indoor unit functions using jumper wires on the PCB.

14-2. Indoor unit (setting by wireless remote controller)

Setting indoor unit functions using a wireless remote controller.

14-3. Indoor unit (setting by wired remote controller)

Setting indoor unit functions using a wired remote controller.

17. Indoor unit installation precautions

1. Specifications

2. Dimensions

3. Installation space

5. Wiring diagram

6. Capacity table

8. Additional charge calculation

9. Airflow

10. Operation noise (sound pressure)

11. Electrical characteristics

12. Safety devices

14. Outdoor unit installation precautions

15. Outdoor unit installation precautions

Fujitsu AGU9RLF Specifications

General IconGeneral
BrandFujitsu
ModelAGU9RLF
CategoryAir Conditioner
LanguageEnglish

Related product manuals