En-4
4.4. Sleep timer
NOTE:
This function is available only when using the wireless remote
controller.
The Sleep timer supports your comfortable sleep by moderating the air
conditioner operation gradually.
The time setting of the Sleep timer changes as follows:
9H
00M
7H
00M
5H
00M
3H
00M
2H
00M
1H
00M
0H
30M
(H:h,M:min)
During the Sleep timer operation, the setting temperature changes as
the following gure.
In Heating mode
Set
temperature
Set time
1 hour
Set time
1 hour
1.5 hour
30 min.
1 °C 2 °C 3 °C 4 °C
2 °C
1 °C
In Cooling or Dry mode
After the set time has elapsed, the air conditioner operation turns o .
5. ENERGY SAVING OPERATIONS
NOTE:
For detailed instructions on how to operate, refer to the operation
manual of the remote controller.
5.1. Economy operation
NOTE:
Depending on the remote controller, this function may not be
available.
It saves more electricity than other operation modes by changing the set
temperature to a moderate setting.
Operation
mode
Setting details
Cooling/Dry
The room temperature will be few degrees higher than
the set temperature
Heating
The room temperature will be few degrees lower than
the set temperature
NOTES:
In the Cooling, Heating, or Dry mode, the maximum output of this
operation is approximately 70% of the usual operation. If the room
is not cooled or heated well during the Economy operation, select
normal operation.
This operation cannot be performed during the temperature
monitoring by the Auto mode.
5.2. Fan control for energy saving
NOTE:
Depending on the remote controller, this function may not be
available.
In the Cooling or Dry operation, when the room temperature reaches the
set temperature, the indoor unit fan rotates intermittently to save power.
This function is deactivated at the time of purchase.
To change the setting, refer to the operation manual of the remote
controller.
Even if the setting is changed, if the fan speed is set to Auto in Cooling
or Dry mode, this function still works to suppress the di usion of
circulated indoor humidity.
5.3. Demand Response
This product is designed to be compatible with Air Conditioning Demand
Response program.
To utilize the function, you need a separate arrangement with your
electricity supplier. Check availability in the place of use.
When your electricity supplier activates one of the following 3 Demand
Response (DR) modes, the air conditioner switches over to the
appropriate operation.
When the DR mode nishes, the air conditioner returns to the operation
set before entering the DR mode.
Details on Demand Response mode
DR mode Description of operation in this mode
DR mode 1 Compressor o .
DR mode 2
electrical energy consumption in 30 minutes:
50 % or less
(compared with rated energy consumption)
DR mode 3
electrical energy consumption in 30 minutes:
75 % or less
(compared with rated energy consumption)
NOTES:
During the DR mode, the cooling or heating performance may be
reduced.
During the DR mode, only the following operations are valid.
- Turning o the operation by the remote controller
-O timer operation
During the DR mode, the Filter sign will not display.
Timer setting error indicator will be prioritized over the DR mode
indicator.
If you have operational issues:
(1) Contact your electricity supplier to check whether they are activating
the DR mode.
(2) Is the air conditioner under the Demand controlling?
Yes
Contact your electricity supplier.
No Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to
your warranty card.)
or
Visit our website (www.fujitsugeneral.com.au).
6. CLEANING AND CARE
CAUTION
Before cleaning the indoor unit, be sure to turn it o
and disconnect all the power supply.
The fan operates at high speed inside the unit and
could result in personal injury.
• If the lter cleaning involves high-place work, consult
the professional technical service personnel.
Do not expose the indoor unit to liquid insecticides or
hair sprays.
Do not stand on slippery, uneven, or unstable
surfaces when you maintain the unit.
When cleaning the unit, do not use water hotter than 40 °C,
harsh abrasive cleansers, or volatile agents like benzene or
thinner.
Cleaning air lter (optional)
NOTES:
• The air lters are optional parts. When purchasing, contact the store
where you purchased this air conditioner.
Compatible the air lters di er depending on the model. For details,
refer to the table below.
model name of indoor unit model name of the air lter
ARTH24KHTA
ARTH30KHTA
ARTH36KHTA
UTD-LF60KA
ARTH45KHTA
ARTH54KHTA
ARTH60KHTA
(Not available)
ARTH60KHTB UTD-LFKA
For how to install and remove the air lter, refer to the instruction
sheet of the air lter.
draft059381067299-01[base9381067237-02OMEN].indd4draft059381067299-01[base9381067237-02OMEN].indd4 2022/10/208:52:322022/10/208:52:32