OPERATING MANUAL
INDOOR UNIT (Wall mounted type)
Keep this manual for future reference.
MODE D’EMPLOI
APPAREIL INTÉRIEUR (Type montage mural)
Conservez ce manuel pour pour toute référence ultérieure.
MANUAL DE FUNCIONAMIENTO
UNIDAD INTERIOR (Tipo montado en pared)
Conserve este manual para posibles consultas futuras.
MANUAL DE FUNCIONAMENTO
UNIDADE INTERIOR (Tipo mural)
Guarde este manual para consulta futura.
BEDIENUNGSANLEITUNG
INNENGERÄT (wandmontierter Typ)
Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf.
MANUALE DI ISTRUZIONI
UNITÀ INTERNA (tipo montato a parete)
Conservare questo manuale per consultazione futura.
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ (Επιτοιχιος τύπος)
Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
ВНУТРЕННИЙ МОДУЛЬ (настенного типа)
Сохраните данное руководство для последующего использования.
KULLANIM KILAVUZU
İÇ ÜNİTE (Duvara monteli tip)
Bu kılavuzu ileride başvurmak üzere saklayın.
9377772084-01_OM.indb cover19377772084-01_OM.indb cover1 2012-6-25 14:19:362012-6-25 14:19:36

Other manuals for Fujitsu Airstage ASYA09GACH

Questions and Answers

  • R
    Rose PadillaAug 7, 2025
    What does it mean when the green light is flashing on my Fujitsu Air Conditioner?
    • S
      sanchezmatthewAug 8, 2025
      The OPERATION indicator lamp (green) on your Fujitsu Air Conditioner may flash for several reasons: * An oil recovery operation is being performed. * An automatic defrosting operation is being performed. The OPERATION indicator lamp (green) and TIMER indicator lamp (orange) may also flash alternately if it has recovered from a power outage, or simultaneously if it is operating in trial operation mode. The OPERATION indicator lamp (green) may light up and the TIMER indicator lamp (orange) may flash to indicate a standby state.
  • A
    adamspaulaAug 12, 2025
    Why is water coming from my Fujitsu Air Conditioner outside?
    • J
      James CarpenterAug 12, 2025
      During Heating operation, water may be produced from the outdoor unit of your Fujitsu Air Conditioner due to the Automatic Defrosting operation.
  • M
    morrisonjohnAug 18, 2025
    Why is my Fujitsu Airstage ASYA09GACH making noise?
    • A
      Amy EsparzaAug 18, 2025
      You may hear noises from your Fujitsu Air Conditioner under several normal conditions. During operation, the sound of refrigerant flowing, a slight squeaking from panel expansion/contraction due to temperature changes, or a sizzling sound during the Automatic Defrosting operation in Heating mode may be audible.
  • J
    Jorge MartinAug 22, 2025
    Why is the airflow weak in my Fujitsu Airstage ASYA09GACH?
    • P
      paulaowenAug 23, 2025
      There are several reasons why the airflow from your Fujitsu Air Conditioner might be weak or stop: * During Heating, the fan may stop temporarily to warm internal parts. * In Heating, if the room gets too warm, the outdoor unit and indoor fan will stop; lower the thermostat setting if you want it warmer. * The airflow may stop for about 10 minutes during oil recovery operation. * The unit will temporarily stop for 4-15 minutes during Automatic Defrosting in Heating mode. * The fan may operate at low speed during Dry operation or when monitoring the room's temperature. * In monitor AUTO operation, the fan runs at low speed.
  • H
    Heather MaynardAug 27, 2025
    Why does my Fujitsu Airstage ASYA09GACH smell?
    • E
      Edwin GarciaAug 27, 2025
      If your Fujitsu Air Conditioner emits a smell, it's likely due to room odors (from furniture, tobacco, etc.) that have been drawn into the unit.
  • K
    Kenneth HatfieldSep 1, 2025
    Why is steam coming out of my Fujitsu Airstage ASYA09GACH?
    • L
      Loretta Nelson DVMSep 1, 2025
      During Heating operation, steam from your Fujitsu Air Conditioner may be seen rising from the outdoor unit because of the Automatic Defrosting operation.

Summary

SAFETY PRECAUTIONS

PRECAUTIONS ON USE

General safety measures and warnings for operating the unit.

PRECAUTIONS ON INSTALLATION

Safety guidelines and warnings related to the unit's installation.

MANUAL AUTO OPERATION

CLEANING AND CARE

TROUBLESHOOTING

Doesnt operate immediately

Common issues when the unit does not start immediately.

Airflow is weak or stops

Reasons for weak or stopped airflow during operation.

The following conditions may not be breakdowns so check again

Doesnt operate at all

Checks to perform if the unit does not operate at all.

Poor Cooling (or Heating) performance

Common causes for reduced cooling or heating performance.

SPECIFICATIONS

Fujitsu Airstage ASYA09GACH Specifications

General IconGeneral
TypeSplit System
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
Power Supply220-240V, 50Hz
Voltage220-240V
Indoor Unit Dimensions (W x H x D)790 x 275 x 203 mm
Outdoor Unit Dimensions (W x H x D)660 x 540 x 290 mm
Indoor Unit Weight9 kg
Noise Level (Outdoor Unit)50 dB