BEDIENUNGSANLEITUNG
INNENGERÄT (wandmontierter Typ)
Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf.
OPERATING MANUAL
INDOOR UNIT (Wall Mounted Type)
Keep this manual for future reference.
MANUAL DE FUNCIONAMIENTO
UNIDAD INTERIOR (Tipo montado en pared)
Conserve este manual para posibles consultas futuras.
MANUALE DI ISTRUZIONI
UNITÀ INTERNA (tipo montato a parete)
Conservare questo manuale per consultazione futura.
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ (Επιτοιχιος Τύπος)
Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά.
MANUAL DE FUNCIONAMENTO
UNIDADE INTERIOR (Tipo mural)
Guarde este manual para consulta futura.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
ВНУТРЕННИЙ МОДУЛЬ (настенного типа)
Сохраните данное руководство для последующего использования.
KULLANIM KILAVUZU
İÇ ÜNİTE (Duvara Monteli Tip)
Bu kılavuzu ileride başvurmak üzere saklayın.
MODE D’EMPLOI
APPAREIL INTÉRIEUR (Type montage mural)
Conservez ce manuel pour pour toute référence ultérieure.
PART NO. 9377772091
Deutsch EnglishEspañolItalianoΕλληνικάPortuguêsРусскийTürkçe Français
ASYA18GACH/ASHA18GACH
ASYA24GACH/ASHA24GACH
ASYA30GACH/ASHA30GACH
9377772091-01_OM.indb cover19377772091-01_OM.indb cover1 6/15/2012 11:33:56 AM6/15/2012 11:33:56 AM

Questions and Answers

  • P
    Phillip RasmussenAug 15, 2025
    What to do if my Fujitsu AIRSTAGE ASYA24GACH has poor cooling or heating performance?
    • R
      Randall WhiteAug 16, 2025
      If your Fujitsu Air Conditioner isn't cooling or heating well, consider these points: * Ensure the room temperature settings (thermostat) are correctly adjusted. * Check if the air filter is dirty and clean it if necessary. * Make sure the air conditioner's inlet or outlet port isn't blocked. * Close any open windows or doors. * If cooling, close curtains to block bright sunlight. * Reduce heat-generating appliances or the number of people in the room. * Increase the fan speed if it's set too low.
  • C
    Clarence HortonAug 18, 2025
    Why does my Fujitsu AIRSTAGE ASYA24GACH airflow is weak or stops?
    • L
      Laura RiceAug 18, 2025
      Weak or stopped airflow in your Fujitsu Air Conditioner can occur due to several reasons: * When heating starts, the indoor unit's fan may temporarily stop to warm up internal parts. * During heating, if the room temperature exceeds the thermostat setting, the outdoor unit and indoor fan will stop. Lower the thermostat if you want to warm the room further. * Airflow may stop for about 10 minutes during oil recovery operation. * The unit will temporarily stop for 4-15 minutes during heating as the automatic defrosting mode operates. * The fan may operate at low speed during dry operation or when monitoring the room's temperature. * In monitor AUTO operation, the fan will operate at low speed.
  • T
    Todd PopeAug 21, 2025
    What to do if the operation mode cannot be changed on my Fujitsu Air Conditioner?
    • S
      Scott KimAug 22, 2025
      If you're unable to change the operation mode on your Fujitsu Air Conditioner, ensure you are not trying to select an operation that conflicts with the priority conditions.
  • S
    Susan MillerAug 25, 2025
    Why is my Fujitsu AIRSTAGE ASYA24GACH not operating immediately?
    • D
      Dana JacksonAug 26, 2025
      Your Fujitsu Air Conditioner might not start immediately because: * If stopped and restarted quickly, the compressor won't operate for about 3 minutes to prevent fuse issues. * After turning the electrical breaker off and on, the protection circuit operates for about 3 minutes, preventing immediate operation.
  • J
    Jeffrey WarrenAug 27, 2025
    Why is the OPERATION indicator lamp flashing on my Fujitsu AIRSTAGE ASYA24GACH?
    • R
      ramirezsabrinaAug 27, 2025
      The OPERATION indicator lamp (green) on your Fujitsu Air Conditioner may be flashing because: * An oil recovery operation is being performed. * An automatic defrosting operation is being performed. Also, the OPERATION indicator lamp (green) and TIMER indicator lamp (orange) may be flashing alternately because it has recovered from a power outage. They may be flashing simultaneously because it is operating in trial operation mode. The OPERATION indicator lamp (green) may be lit and the TIMER indicator lamp (orange) may be flashing because the unit is in standby state.
  • R
    raybrandiAug 30, 2025
    Why is water produced from my Fujitsu AIRSTAGE ASYA24GACH Air Conditioner outdoor unit?
    • M
      Mario BrooksAug 30, 2025
      During heating operation, water may be produced from the outdoor unit due to the automatic defrosting operation.
  • S
    Stacy BooneSep 2, 2025
    Why does my Fujitsu Air Conditioner make noise?
    • D
      David RobertsSep 2, 2025
      Your Fujitsu Air Conditioner might produce sounds for several reasons: * You may hear sounds of water flowing from the indoor unit, and the operation sound becomes loud. These are the sounds of the flowing of refrigerant. * A slight squeaking sound may occur due to minute expansion and contraction of the panel because of temperature changes. * During heating, a sizzling sound might be heard occasionally, which is produced by the automatic defrosting operation.
  • S
    Samuel HernandezSep 5, 2025
    Why does my Fujitsu AIRSTAGE ASYA24GACH Air Conditioner smell?
    • T
      Tammy OwensSep 5, 2025
      A smell emitted from your Fujitsu Air Conditioner's indoor unit results from room odors (furniture, tobacco, etc.) that have been taken into the air conditioner.
  • S
    Sandra MontgomerySep 8, 2025
    Why is fog coming out of my Fujitsu AIRSTAGE ASYA24GACH Air Conditioner indoor unit?
    • D
      Dustin MartinezSep 9, 2025
      During cooling operation, a thin mist emitted from the indoor unit results from the sudden cooling of room air, causing condensation and misting.
  • P
    Preston JenkinsSep 12, 2025
    Why is steam coming out of my Fujitsu AIRSTAGE ASYA24GACH indoor unit?
    • K
      Kathleen WileySep 12, 2025
      During heating, if steam comes out of the indoor unit, it is due to the automatic defrosting operation.

Summary

SAFETY PRECAUTIONS

PRECAUTIONS ON USE

Guidelines for safe operation and avoiding hazards during air conditioner use.

PRECAUTIONS ON INSTALLATION

Instructions for safe installation, emphasizing professional service and grounding.

NAME OF PARTS

ADJUSTING THE DIRECTION OF AIR CIRCULATION

OPERATING TIPS

Operation and Performance

Details on system states, ambient conditions, and heating performance.

CLEANING AND CARE

Cleaning the Air Filter

Step-by-step guide for removing, cleaning, and reinstalling air filters.

Cleaning the Intake Grille

Instructions on how to remove, clean, and reattach the intake grille.

AIR FILTER MAINTENANCE AND REPLACEMENT

Air Cleaning Filter Installation

Procedures for installing disposable air cleaning filters.

Replacing dirty Air cleaning filters

Steps for replacing used air cleaning filters with new ones.

In regard to the Air Cleaning Filters

Information on disposable and deodorizing filters, replacement intervals.

Maintenance of Deodorizing Filters

How to clean deodorizing filters to maintain their effect.

TROUBLESHOOTING

SPECIFICATIONS

Fujitsu AIRSTAGE ASYA24GACH Specifications

General IconGeneral
TypeSplit System
SeriesAIRSTAGE
ModelASYA24GACH
Power Supply220-240 V, 50 Hz
RefrigerantR410A
Outdoor Unit Noise Level52 dB(A)
Seasonal Energy Efficiency Ratio (SEER)5.7
Coefficient of Performance (Heating)3.8
Air Flow (Indoor Unit)600 CFM