EasyManua.ls Logo

Fujitsu AO G09KATA Series - Compressor Frequency at Normal Start-Up

Fujitsu AO G09KATA Series
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-4. Compressor frequency at normal start-up
¢ Models: AOYG09KATA, AOYG12KATA, AOYG14KATA, and
AOYG18KATA
Compressor frequency soon after starting is controlled as below.
Frequency I
Frequency II
Frequency III
Frequency IV
Frequency V
Frequency VI
Frequency VII
Time 1
Time 2 Time 3
Time 4
Time 5
Time 6
Time 7
Frequency (rps)
I II III IV V VI VII
45 56 68 77 84 93 103
Time (sec)
1 2 3 4 5 6 7
60 140 170 220 280 360 430
1-4. Compressor frequency at normal start-up - (01-5) - 1. Compressor frequency control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Related product manuals