¢ Mini duct type
• Rotation number range of compressor
Unit: rps
Model name Outdoor temperature zone Operating rotation number
ARXG07KSLAP
ARXG09KSLAP
ARXG12KSLAP
X zone 54
J zone 54
ARXG14KSLAP
ARXG18KSLAP
Y zone 0
• Compressor control based on room temperature
Ts+0.5°C
Ts -1.5°C
Ts-0.5°C
Ts+1.5°C
X zone
J zone
Y zone
Room temperature drops
Room temperature rises
Ts: Set temperature
¢ Slim duct type
• Rotation number range of compressor
Unit: rps
Model name Outdoor temperature zone Operating rotation number
ARXG07KLLAP
ARXG09KLLAP
ARXG12KLLAP
X zone 54
J zone 54
ARXG14KLLAP
ARXG18KLLAP
Y zone 0
• Compressor control based on room temperature
Ts+0.5°C
Ts -1.5°C
Ts-0.5°C
Ts+1.5°C
X zone
J zone
Y zone
Room temperature drops
Room temperature rises
Ts: Set temperature
1-3. Dry operation
- (04-11) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND