¢ Wall mounted type (For KGTB)
• Rotation number range of compressor
Unit: rps
Connected outdoor unit model
name
Minimum rotation number Maximum rotation number
AOHG14KBTA2 12 110
AOHG18KBTA2 8 120
• Limit of maximum speed based on outdoor temperature
A zone
26°C
B zone
C zone
D zone
23°C
20°C
Unit: rps
– Model: AOHG14KBTA2
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ASHG07KGTB
ASHG09KGTB
ASHG12KGTB
ASHG14KGTB
A zone 89 67 58 50
B zone 89 77 67 58
C zone 110 96 83 72
D zone 110 110 110 110
– Model: AOHG18KBTA2
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ASHG07KGTB
ASHG09KGTB
ASHG12KGTB
ASHG14KGTB
A zone 94 68 58 50
B zone 94 80 68 58
C zone 120 102 87 74
D zone 120 120 120 120