Heating operation
Switch the airflow AUTO, and the indoor fan motor will run according to a room temperature, as be-
low.
On the other hand, if switched in HIGH—QUIET, the indoor motor will run at a constant airflow of
HEAT operation modes QUIET, LOW, MED, HIGH as shown in “Fan speed” above.
Airflow change over (Heating: Auto)
When the room
temperature rises
When the room
temperature drops
LOW mode
MED mode
HIGH mode
Tr - Ts ≥ -1°C
-2°C > Tr - Ts
Tr - Ts ≥ -1.5°C
-1.5°C > Tr - Ts ≥ -2.5°C
-2.5°C > Tr - Ts
-1°C > Tr - Ts ≥ -2°C
Cool air prevention control (heating mode)
The maximum value of the indoor fan speed is set as shown below, based on the detected tempera-
ture by the indoor heat exchanger sensor on heating mode.
Normal operation
Indoor heat exchanger
temperature rises
S-LOW
Indoor heat exchanger
temperature drops
37°C
29°C
32°C
24°C
Setting fan mode
LOW
or setting fan mode*
*: Lower speed is selected.
13 minutes later:
Indoor heat exchanger
temperature rises
Indoor heat exchanger
temperature drops
37°C
29°C
32°C
24°C
Setting fan mode
LOW
or setting fan mode*
*: Lower speed is selected.
LOW
or setting fan mode*
10 °C HEAT operation
Indoor heat exchanger
temperature rises
Indoor heat exchanger
temperature drops
37°C
32°C
LOW
AUTO
3-1. Indoor fan control
- (04-33) - 3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu AO G12KATA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AO G12KATA Series and is the answer not in the manual?

Fujitsu AO G12KATA Series Specifications

General IconGeneral
BrandFujitsu
ModelAO G12KATA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals