1-5. Compressor frequency limitation by outdoor temperature
The minimum compressor frequency is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
38°C
E zone
19°C
D zone
10°C
C zone
B zone
A zone
0°C
-10°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOYG18KATA
A zone 36 rps
B zone 36 rps
C zone 28 rps
D zone 1 rps
E zone 1 rps
F zone 20 rps
AOYG22KATA
A zone 30 rps
B zone 30 rps
C zone 22 rps
D zone 16 rps
E zone 13 rps
F zone 25 rps