Heat Ex. Outlet / Middle Temp.
Thermistor Error
OK
OK
DC
P1
THERMISTOR
(PIPE )
THERMISTOR
(DIS.PIPE.)
BLACK
BLACK
BLACK
BLACK
4321
4321
Heat exchanger Outlet / Middle temperature
thermistor
Heat exchanger outlet temperature thermistor short or open detected
Heat exchanger middle temperature thermistor short or open detected
Check Point 1 : Check the connector connection and cable open
Connector connection state check
Cable open check
Check Point 2 : Check the thermistor
Thermistor characteristics check
(Disconnect the thermistor from the PCB and check.)
* For the thermistor characteristics, refer to the "Service Parts Information 8".
Check Point 3 : Check voltage of Main PCB (DC5.0V)
Main PCB P1 :1-2 voltage value =5V
Main PCB P10:1-2 voltage value =5V
Remove the thermistor from Main PCB, check the voltage.
If the voltage does not appear, replace Main PCB,
and execute the check operation again.
02-24
Trouble shooting 24
Detective Actuators: Detective details:
OUTDOOR UNIT Error Method:
Indicate or Display:
Error code : 73 Outdoor unit : No indication
P10
THERMISTOR
(PIPE MID )
BLACK
BLACK
321
321
1. Connector connection failure, open
2. Thermistor failure
3. Main PCB failure
Forecast of Cause :

Other manuals for Fujitsu AO G18KATA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AO G18KATA Series and is the answer not in the manual?

Fujitsu AO G18KATA Series Specifications

General IconGeneral
BrandFujitsu
ModelAO G18KATA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals