Page #30 background imageLoading...
Page #30 background image
- (01 - 27) -
FLOOR TYPE
AGU9-15RLF
FLOOR TYPE
AGU9-15RLF
FUNCTION DETAILS
Functions
1) Filter sign
2) Vertical airow direction range control
3) Room temperature control for indoor unit sensor
4) Auto restart
5) Room temperature sensor switching
6) Remote controller custom code
7) External input control
8) Room temperature sensor switching (Aux.)
9) Indoor unit fan control for energy saving for cooling
10) Room temperature control for wired remote controller sensor
11) Heat Insulation condition (building insulation)
1) Filter sign
Select appropriate intervals for displaying the lter sign on the indoor unit according to the
estimated amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
... Factory setting)
Function number Setting value Setting description
11
00 Standard (400 hours)
01 Long interval (1000 hours)
02 Short interval (200 hours)
03 No indication
2) Vertical airow direction range control
In a concealed installation, change the setting to "Fixed" (02) to restrict the movement of the
upper air outlet so that the airow is only towards the horizontal direction.
(
... Factory setting)
Function number Setting value Setting description
23
00 Standard
01 (Setting prohibited)
02 Fixed (Concealed)

Other manuals for Fujitsu AOU12RLFF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOU12RLFF and is the answer not in the manual?

Fujitsu AOU12RLFF Specifications

General IconGeneral
BrandFujitsu
ModelAOU12RLFF
CategoryAir Conditioner
LanguageEnglish

Related product manuals