SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
INVERTER
SERVICE
INSTRUCTION
R410A
ASU 9RLF
ASU12RLF
ASU15RLS
AOU 9RLFW
AOU12RLFW
AOU15RLS

Table of Contents

Other manuals for Fujitsu AOU12RLFW

Questions and Answers:

Fujitsu AOU12RLFW Specifications

General IconGeneral
StyleSplit-type
ColorWhite
Features-
Cooling CapacityRated: 2.637 kW
Min/Max: 0.50-3.20 kW1700-10900 BTU/h
Min/Max Cooling 2.20/8.00 kW?9.5 (2.8 - 11.2) kW
2.80 (0.84-3.28) kW76
22.40 kW7.80/7.70 kW
26600/26
Cooling Temperature: 0 - 115 F2.64 (1.30 ~ 2.78) kW
9000 (4
2270 (1
Heating CapacityRated: 3.516 kW
Min/Max: 0.50-4.40 kW1700-15000 BTU/h
Min/Max Heating 1.90/9.00 kW?10.8 (2.7 - 12.7) kW
25.20 kW-
heating Temperature: -4 - 75 F-
Moisture Removal2.75 (1.3) pints/h (l/h)
Fan Airflow RateCooling/Heating: High Speed 441(750) CFM (m^3/h)
High / Mid / Low: [CMH] (C) 1050/954/858 (H) 1050/954/858 CMHIndoor (Cooling): High 1850 m³/h
Outdoor (Cooling): High 3750 m³/hQlo: 5.5 m3/min
SHi: 11.7 m3/minHEAT PUMP & HEAT RECOVERY
635 cfm182 - 294 CFM
SL: 138 (3.9) cfm (m³/min)Indoor (Cooling): High 1870 m³/h
Operation Temperature RangeCooling: 64 to 90 (18 to 32) F(C)
Heating: 88 (30) or lessCooling: 23 ~ 118 F;
Heating: -4 ~ 75 F-
Heating: -15 to 24 °CIndoor: 16-32 °C
Outdoor: 16-43 °CCooling (?): 10.0 ~ 45.0 ?
Heating (?): 10.0 ~ 45.0 ?-
Sound Pressure LevelCooling/Heating 43 dB(A)
Indoor (Heating): High 44 dB(A)Middle 40 dB(A)
Refrigerant TypeR410a
Refrigerant Charge1 lb 14 oz
Annual Energy Consumption-
Heating: 2904 kWh/a-
Power Input-
Heating: 0.35/2.40/3.95 kWCooling: 2.960 kW
Heating: 2.880 kW760 (225-920) W
Heating: 4.12 W-
Frequency60 Hz
Voltage208/230 V
Current4.2 A
Heating: 16.4 ACooling: 2.0/11.1/17.0 A
Heating: 2.0/10.7/17.0 ACooling: 22.60 A
Heating: 22.60 A3.6 A
Heating: 6.60 A-
Battery Life-
Battery Capacity-
Depth203 mm
Height280 mm
Width790 mm
Net Weight18 (8) lb (kg)

Summary

Description of Each Control Operation

1. Cooling Operation

Explains compressor frequency control based on room temperature for cooling.

2. Heating Operation

Explains compressor frequency control based on room temperature for heating.

3. Dry Operation

Details compressor frequency control based on room temperature sensor in dry mode.

4. Auto Changeover Operation

Describes automatic mode switching based on temperature changes.

5. Indoor Fan Control

Covers fan speed settings, operation modes, and temperature-based control.

6. Outdoor Fan Control

Details outdoor fan motor types and speed settings based on zones.

7. Louver Control

Explains vertical louver adjustments and swing operation.

8. Compressor Control

Covers compressor frequency ranges and startup control procedures.

9. Timer Operation Control

Explains ON/OFF, program, and sleep timer operations.

10. Electronic Expansion Valve Control

Details the control mechanism of the electronic expansion valve.

11. Test Operation Control

Outlines the procedure for performing a test operation.

12. Prevent to Restart for 3 Minutes

Describes the compressor's 3-minute restart prevention feature.

13. Four-Way Valve Extension Select

Explains four-way valve switching during mode transitions.

14. Auto Restart

Details the system's automatic restart function after power loss.

15. Manual Auto Operation

Explains indoor unit operation without a remote control.

16. Forced Cooling Operation

Describes the forced cooling operation mode.

17. Compressor Preheating

Explains the compressor preheating function.

18. Minimum Heat Operation

Details the minimum heat operation mode.

19. Economy Operation

Explains the economy operation mode.

20. Defrost Operation Control

Covers conditions for starting and completing defrost operations.

21. Off Defrost Operation Control

Specifies conditions for off-defrost operation and its completion.

22. Various Protections

Details various protection controls like discharge gas temp and current release.

Trouble Shooting

2-1 Error Display

Explains error displays on wired remote, outdoor, and indoor units.

2-2 Trouble Shooting With Error Code

Provides detailed troubleshooting steps for specific error codes.

2-3 Trouble Shooting With No Error Code

Guides troubleshooting for issues without specific error codes like no power.

2-4 Service Parts Information

Offers diagnostic methods for key components like compressors and motors.

Appending Data

3-1 Function Setting

Details configuration of indoor unit settings like filter signs and temperature corrections.

3-2 Thermistor Resistance Values

Lists resistance values for indoor and outdoor unit thermistors.