General IconGeneral
RefrigerantR410A
Cooling Capacity15, 000 BTU/h
Heating Seasonal Performance Factor (HSPF)10.0
Outdoor Unit Noise Level49 dB(A)
Heating Capacity18, 000 BTU/h

Summary

Description of Each Control Operation

Cooling Operation Control

Controls compressor frequency based on room temp difference from set temp.

Heating Operation Control

Controls compressor frequency based on room temp difference from set temp.

Dry Operation Indoor Unit Control

Controls compressor frequency based on room temp sensor for dry mode.

Auto Changeover Operation

Automatically switches between heating, cooling, dry, and monitoring modes based on temperature.

Indoor Fan Speed Control

Manages fan speed settings (AUTO, QUIET, LOW, MED, HIGH) for different modes.

Heating Operation Indoor Fan Control

Controls indoor fan speed based on room temperature in heating mode.

Outdoor Fan Speed Control

Regulates outdoor fan speed based on operating mode and outdoor temperature.

Vertical Louver Direction Control

Adjusts vertical airflow direction for optimal air distribution in different modes.

Compressor Operation Frequency Range

Defines the minimum and maximum operating frequencies for the compressor.

Compressor Frequency Control at Start-up

Details the step-by-step frequency adjustment of the compressor during startup.

Timer Operation Control

Outlines available timer functions: ON/OFF, Program, and Sleep timers.

Sleep Timer Operation

Describes automatic temperature adjustments and operation stop for energy saving during sleep.

Electronic Expansion Valve (EEV) Control

Manages EEV opening based on operating conditions for precise refrigerant flow.

Test Operation Mode

Explains how to activate and use the test operation mode for system checks.

3-Minute Restart Prevention

Prevents compressor restart for a specified duration after stopping for protection.

Four-Way Valve Switching

Details the switching process of the four-way valve between cooling and heating modes.

Auto Restart Functionality

Restores operation with previous settings after a power interruption.

Manual Auto Operation

Allows operation control via the indoor unit body when the remote is lost or fails.

Forced Cooling Operation

Initiates cooling operation regardless of room temperature for a set duration.

Compressor Preheating

Warms the compressor before operation in cold conditions for better performance.

Minimum Heat Operation

Maintains a minimum heating temperature level.

Economy Operation Mode

Optimizes operation for energy saving by adjusting target temperatures.

Defrost Operation Control

Specifies conditions that trigger the defrost cycle to remove frost.

Off Defrost Operation Control

Explains conditions for automatic defrosting when heating operation stops.

Discharge Gas Temperature Overrise Prevention

Protects the compressor by controlling frequency or stopping it based on discharge gas temperature.

Current Release Control

Manages compressor frequency to prevent exceeding current limits based on outdoor temperature.

Antifreezing Control

Prevents indoor coil freezing by controlling compressor frequency in cooling/dry modes.

Cooling Pressure Overrise Protection

Stops compressor and fan if outdoor heat exchanger temperature becomes excessively high.

High Temperature Release Control (Heating Mode)

Controls compressor frequency based on indoor heat exchanger temperature during heating.

Trouble Shooting

Error Display Overview

General information on error codes and their display methods.

Wired Remote Controller Error Display

Explains error codes displayed on the wired remote controller and self-diagnosis.

Outdoor Unit Error Display

Details LED flashing patterns for outdoor unit errors and their corresponding trouble shooting codes.

Indoor Unit Error Display

Shows error content and corresponding lamp flashing patterns for indoor unit issues.

Troubleshooting Serial Communication Errors

Steps to diagnose and resolve serial communication errors involving the outdoor unit.

Troubleshooting Remote Controller Communication Error

Guides through diagnosing and fixing communication errors between the remote controller and the indoor unit.

Troubleshooting Indoor Unit Main PCB Error

Outlines steps to diagnose and resolve errors related to the indoor unit's main PCB.

Troubleshooting Room Temperature Sensor Error

Details how to diagnose and resolve errors caused by a faulty room temperature sensor.

Troubleshooting Indoor Unit Heat Exchanger Sensor Error

Guides through diagnosing and resolving errors related to the indoor unit's heat exchanger sensor.

Troubleshooting Indoor Unit Fan Motor Error

Provides steps to diagnose and resolve errors related to the indoor unit's fan motor.

Troubleshooting Outdoor Unit Main PCB Error

Outlines steps to diagnose and resolve errors related to the outdoor unit's main PCB.

Troubleshooting PFC Circuit Error

Guides through diagnosing and resolving errors related to the PFC circuit in the outdoor unit.

Troubleshooting IPM Error

Details steps to diagnose and resolve errors related to the IPM module in the outdoor unit.

Troubleshooting Discharge Thermistor Error

Guides through diagnosing and resolving errors caused by a faulty discharge pipe temperature thermistor.

Troubleshooting Outdoor Unit Heat Exchanger Sensor Error

Outlines steps to diagnose and resolve errors related to the outdoor unit's heat exchanger sensor.

Troubleshooting Outdoor Thermistor Error

Guides through diagnosing and resolving errors caused by a faulty outdoor temperature thermistor.

Troubleshooting Current Sensor Error

Details steps to diagnose and resolve errors related to the input current sensor.

Troubleshooting Trip Detection

Guides through diagnosing and resolving issues related to trip detection errors.

Troubleshooting Compressor Motor Control Error

Outlines steps to diagnose and resolve errors related to compressor motor control.

Troubleshooting Outdoor Unit Fan Motor Error

Guides through diagnosing and resolving errors related to the outdoor unit's fan motor.

Troubleshooting 4-Way Valve Error

Details steps to diagnose and resolve errors related to the 4-way valve.

Troubleshooting Discharge Temperature Error

Guides through diagnosing and resolving errors related to discharge temperature.

Troubleshooting Indoor Unit No Power

Provides steps to diagnose and resolve issues when the indoor unit has no power.

Troubleshooting Outdoor Unit No Power

Guides through diagnosing and resolving issues when the outdoor unit has no power.

Troubleshooting No Operation (Power ON)

Details steps to diagnose and resolve issues when the unit has power but no operation.

Troubleshooting No Cooling or Heating

Provides steps to diagnose and resolve issues when the unit fails to cool or heat.

Troubleshooting Abnormal Noise

Guides through diagnosing and resolving abnormal noise issues from the unit.

Troubleshooting Water Leaking

Details steps to diagnose and resolve water leaking issues.

Service Parts Information: Compressor

Provides diagnostic methods for compressor issues and part replacement guidance.

Service Parts Information: Inverter Compressor

Details connection checks and winding resistance for inverter compressors.

Service Parts Information: Electronic Expansion Valve (EEV)

Outlines checks for EEV connections, coil resistance, voltage, and operation.

Service Parts Information: Indoor Unit Fan Motor

Provides checks for indoor fan motor rotation and resistance.

Service Parts Information: Outdoor Unit Fan Motor

Details checks for outdoor fan motor rotation and resistance.

Appending Data

Indoor Unit Function Settings

Explains how to set various functions for the indoor unit via the remote control.

Filter Sign Setting

Configures the filter cleaning reminder interval or disables the display.

Cooler Room Temperature Correction

Allows adjustment of the room temperature sensor reading for cooling mode.

Heater Room Temperature Correction

Allows adjustment of the room temperature sensor reading for heating mode.

Auto Restart Function Setting

Enables or disables the automatic system restart after a power outage.

Indoor Temperature Sensor Switching Function

Selects between indoor unit or remote controller sensor for temperature control.

Remote Controller Signal Code Setting

Configures the signal code to match the remote controller with the indoor unit.

External Input Control Setting

Configures the unit to operate or stop based on external input signals.

Function Setting Procedure for Wireless Remote

Step-by-step guide to change function settings using the wireless remote controller.

Custom Remote Controller Code Setting

Explains how to set custom signal codes for the remote controller.

Indoor Unit Thermistor Resistance Values

Provides resistance values for room and heat exchanger thermistors at various temperatures.

Outdoor Unit Thermistor Resistance Values

Lists resistance values for discharge, heat exchanger, and outdoor thermistors.