AIR CONDITIONER
Multi: 2, 3, 4 rooms type
DESIGN & TECHNICAL MANUAL
INDOOR
AUU7RLF
AUU9RLF
AUU12RLF
AUU18RLF
ARU7RLF
ARU9RLF
ARU12RLF
ARU18RLF ARU24RLF
ASU7RLF1
ASU9RLF1
ASU12RLF1
ASU15RLF1
ASU7RLF*
ASU9RLF*
ASU12RLF*
ASU9RLS2*
ASU12RLS2*
ASU15RLS2*
ASU18RLF
ASU24RLF
AGU9RLF
AGU12RLF
AGU15RLF
*: AOU36RLXFZ1 is not connectable.
OUTDOOR
AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ1
DR_MU008EF_07
2018.06.14

Table of Contents

Other manuals for Fujitsu AOU18RLXFZ

Questions and Answers

  • K
    kstevensonAug 12, 2025
    What to do if my Fujitsu AOU18RLXFZ remote is not working due to a communication error?
    • D
      David MorganAug 12, 2025
      If you're experiencing a Wired Remote Controller Communication Error with your Fujitsu Air Conditioner, check the voltage. If it's DC12V, the remote control has failed and should be replaced. If it's DC 0V, the Controller PCB has failed and should be replaced after rechecking the remote control.
  • S
    Samantha MedinaAug 16, 2025
    What to do if my Fujitsu Air Conditioner has a drainage error?
    • R
      Richard TranAug 17, 2025
      If your Fujitsu Air Conditioner is experiencing drainage issues, start by inspecting the float switch for proper operation using a meter to check its on/off switching. If the float switch is defective, replace it. Also, examine the drain hose for any clogs and clear them if necessary. If these steps don't resolve the issue, consider replacing the controller PCB.
  • J
    James AllisonAug 20, 2025
    How to fix a Fujitsu Air Conditioner indoor unit fan motor error?
    • L
      leslie62Aug 20, 2025
      If you're encountering an indoor unit fan motor error with your Fujitsu Air Conditioner, check first the fan and bearing. If either is damaged, replace them. If the motor itself is faulty, replace the indoor unit fan motor. If these steps do not resolve the issue, replace the controller PCB.
  • D
    daniel74Aug 25, 2025
    What to do if my Fujitsu AOU18RLXFZ Air Conditioner shows an indoor room thermistor error?
    • M
      Misty SmithAug 25, 2025
      If your Fujitsu Air Conditioner displays an indoor room thermistor error, begin by checking the connector to ensure it is securely attached and properly connected, and verify that the thermistor cable is not open. If the thermistor is either open or shorted, replace it and then reset the power.
  • A
    Amanda LarsonAug 27, 2025
    How to troubleshoot an Indoor Unit Model Information Error on my Fujitsu Air Conditioner?
    • D
      David DonovanAug 27, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Model Information Error, check for external causes such as noise and ensure the ground connection is properly connected. Also, inspect all connectors for looseness or incorrect wiring, and check the PCB for any shorts or corrosion. If the problem persists, consider replacing the Controller PCB.
  • C
    Christine DavisAug 31, 2025
    What does an Indoor Unit Capacity Error mean on my Fujitsu Air Conditioner?
    • L
      Lauren ZamoraSep 1, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Capacity Error, first verify the total capacity of the connected indoor units. If an abnormal condition is found, correct it by referring to the Installation Manual or Design & Technical Manual. If the problem persists, replace the Main PCB of the Outdoor unit.
  • S
    Susan ChangSep 4, 2025
    How to fix a Serial Communication Error (Serial Reverse Transfer Error) on a Fujitsu AOU18RLXFZ?
    • A
      Alexis WestSep 4, 2025
      If your Fujitsu Air Conditioner displays a Serial Communication Error (Serial Reverse Transfer Error), check all connection lines between the indoor and outdoor units for any looseness or disconnections, referring to the Installation Manual or Data & Technical Manual for correction. Also, check the voltage of the power supply, ensuring it appears at the outdoor unit terminal L1 - L2 within the range of AC187V - 253V. Check that the indicated value swings between AC90V and AC270V at outdoor unit terminal 1 - 3. If the outdoor fan motor, active filter module, or IPM is abnormal, replace the corresponding part. If all parts are normal, replace the Main PCB.
  • D
    David GraySep 8, 2025
    How to resolve a Damper (Open/Close) simultaneous detection Limit switch error on a Fujitsu AOU18RLXFZ Air Conditioner?
    • R
      ramosadamSep 8, 2025
      If your Fujitsu Air Conditioner displays a Damper(Open/Close) simultaneous detection Limit switch error, replace the limit switch if it is defective. If the problem persists, replace the Controller PCB.

Summary

Part 1. INDOOR UNIT

1. Model lineup

Overview of available indoor unit models and their types.

2. Specifications

Detailed technical specifications for various indoor unit types.

9. Electrical characteristics

Electrical specifications including power supply, current, and wiring.

10. Safety devices

Protection mechanisms and safety devices integrated into indoor units.

14. Function settings

Adjusting indoor unit functions via remote controller or jumper wires.

17. Indoor unit installation precautions

General precautions and points to remember when installing indoor units.

Part 2. OUTDOOR UNIT (2 ROOMS TYPE)

Part 3. OUTDOOR UNIT (3 ROOMS TYPE)

Part 4. OUTDOOR UNIT (4 ROOMS TYPE)

1. Specifications

Detailed specifications for the AOU36RLXFZ1 outdoor unit.

3. Installation space

Requirements for installation space around the outdoor unit.

6. Capacity table

Capacity tables for various combinations of indoor and outdoor units.