EasyManuals Logo

Fujitsu AOU18RLQ Service Manual

Fujitsu AOU18RLQ
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
Outdoor Unit Low Pressure Value and Outdoor Total Electric Current Curve (Cooling)
Model Name : ASU18RLQ
[Condition]
Ambient
temperature
Indoor / Outdoor - Same temperature
Refrigerant
amount
Standard amount
Piping 7.5m (Height difference 1m)
Power
voltage
60Hz - 230V
Operation
condition
TEST mode (Cooling), Hi Fan, Horizontal direction, Front air flow
Measuring
method
Caution
Start operation with the condition of the Indoor Unit air filter clean.
[Constant Frequency Operation Method (Test mode)]
1. Operate on Colling mode, and press TEST button of remote control.
2. Operate continuously for 30 minutes. (After 60 minutes of operation, Test mode is released automatically.)
(1) Indoor/Outdoor Temperature - Outdoor Low Pressure Curve
ASU18RLQ
(2) Indoor/Outdoor Temperature - Outdoor Total Electric Current Curve
ASU18RLQ
Measure the low pressure with the pressure meter at the service valve. Measure the
outdoor unit overall current with the current clamp meter at Power Cable.
0.7
0.8
0.9
1
1.1
1.2
1.3
In/Outdoor ambient temperature °F(°C)
Outdoor Low Pressure (Mpa)
Relative Humidity 50%
Relative Humidity 60%
Relative Humidity 70%
4
4.5
5
5.5
6
In/Outdoor ambient temperature °F(°C)
Outdoor Total Electric Current (A)
Relative Humidity 50%
Relative Humidity 60%
Relative Humidity 70%
length
08-04
59
(15)
68
(20)
77
(25)
86
(30)
95
(35)
59
(15)
68
(20)
77
(25)
86
(30)
95
(35)

Other manuals for Fujitsu AOU18RLQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOU18RLQ and is the answer not in the manual?

Fujitsu AOU18RLQ Specifications

General IconGeneral
BrandFujitsu
ModelAOU18RLQ
CategoryAir Conditioner
LanguageEnglish

Related product manuals