11. Safety devices
Type of
protection
Protection form
Model
AOUH09LMAH1 AOUH12LMAH1
Circuit
protection
Current fuse (Main PCB)
250 V, 15 A
250 V, 5 A
Current fuse (Out of PCB) 250 V, 3.15 A
Fan motor
protection
Thermal protection program
Activate
217.4±32.4 °F (103±18°C)
Fan motor stop
Reset
203±32.4 °F (95±18 °C)
Fan motor restart
Compressor
protection
Thermal protection program
(Discharge temp.)
Activate
230 °F (110 °C)
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY mode)
Activate
5 °F (-15°C)
Compressor stop
Reset
14 °F (-10°C)
Compressor restart
- 77 -
11. Safety devices
OUTDOOR UNIT
AOUG09-12LMAH1
OUTDOOR UNIT
AOUG09-12LMAH1

Other manuals for Fujitsu AOUH09LMAH1