EasyManua.ls Logo

Fujitsu AOUH12LPAS1 - Page 95

Fujitsu AOUH12LPAS1
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heating mode
F zone
E zone
D zone
C zone
B zone
A zone
66.2°F
(19°C)
32.0°F
(0°C)
5.0°F
(-15°C)
-13.0°F
(-25°C)
41.0°F
(5°C)
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOUH09LPAS1
A zone 43 rps
B zone 43 rps
C zone 30 rps
D zone 18 rps
E zone 16 rps
F zone 16 rps
AOUH12LPAS1
A zone 37 rps
B zone 37 rps
C zone 36 rps
D zone 15 rps
E zone 15 rps
F zone 1 rps
1-5. Limitation of compressor rotation number by outdoor temperature - (04-7) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu AOUH12LPAS1

Related product manuals