EasyManua.ls Logo

Fujitsu AOUH24LMAS1 - Rotation Number of Compressor Limitation by Outdoor Temperature

Fujitsu AOUH24LMAS1
215 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
E zone
D zone
C zone
B zone
A zone
G zone
J zone
H zone
I zone
87.8°F
(31°C)
35.6°F
(2°C)
69.8°F
(21°C)
44.6°F
(7°C)
23.0°F
(-5°C)
5.0°F
(-15°C)
14.0°F
(-10°C)
100.4°F
(38°C)
107.6°F
(42°C)
K zone
55.4°F
(13°C)
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOUH18LMAS1
A zone 55 rps
B zone 50 rps
C zone 36 rps
D zone 34 rps
E zone 30 rps
F zone 26 rps
G zone 19 rps
H zone 19 rps
I zone 21 rps
J zone 24 rps
K zone 29 rps
AOUH24LMAS1
A zone 60 rps
B zone 55 rps
C zone 52 rps
D zone 45 rps
E zone 36 rps
F zone 28 rps
G zone 21 rps
H zone 19 rps
I zone 21 rps
J zone 24 rps
K zone 29 rps
1-5. Rotation number of compressor limitation by outdoor temperature - (04-5) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu AOUH24LMAS1

Related product manuals