Type
Wall mounted
Inverter heat pump
Model name ASUH18LMAS ASUH24LMAS
Operation range
Cooling
°F (°C) 64 to 90 (18 to 32)
%RH 80 or less
Heating °F (°C) 86 (30) or less
Remote controller type
→ireless (→ired, Mobile app*
4
[FGLair
] [option])
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 80°FDB (26.67°CDB) /67°F→B (19.44°C→B), and outdoor temperature of 95°FDB (35°CDB) / 75°F→B (23.9°C→B).
Heating: Indoor temperature of 70°FDB (21.11°CDB) /59°F→B (15.56°C→B), and outdoor temperature of 47°FDB (8.33°CDB) /43°F→B (6.11°C→B).
*
1
: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB) /60°F→B (15.56°C→B), and outdoor temperature of 17°FDB (-8.33°CDB) /15°F→B (-9.44°C→B).
Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*
2
: Maximum current is maximum value when operated within the operation range.
*
3
: Sound pressure level:
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
*
4
: Available on Google Play
store or on App Store
®
. Optional →LAN adapter is also required. For details, refer to the setting manual.