22003.11.26
HI-S PE E D (r.p.m .) 42 - 42 COOL 42 - 42 HE A T 42 - 42
IN DOOR U NIT
M E D-S PE ED (r.p.m.) 40 - 40 COOL 40 - 40 HE A T 40 - 40
LO-S PE ED (r.p.m .) 39 - 39 COOL 39 - 39 HE A T 34 - 34
S UPE R QU IE T (r.p.m.) 37 - 37 COOL 37 - 37 HE A T 32 - 32
OU TDOOR U N IT (r.p.m.) 47 - 48 COOL 47 - 48 HE A T 49 - 49
N OIS E LE V EL
Note : Noise was measured in accordance with JIS standards, Japan.
B etween 7.5 m and 15 m, when us ing a connection pipe other than that in the table,
charge additional refrigerant with 20 g /1 m as the criteria.
ADDIT IONA L R E FR IG E RA NT CHA R G E
R efrigerant suitable for a piping length of 7.5 m is charged in the outdoor unit at the factory.
W hen the piping is longer than 7.5 m , additional charging is necessary.
For the additional amount, s ee the table below.
PIPE LE N G TH 7.5 m 10 m 15 m
ADDIT ION A L RE FR IG E R A N T None 50 g 150 g
The m aximum length of the piping is 15 m . If the units are further apart than this ,
correct operation can not be guaranteed.