42003.11.26
3-Way valve
(with charging port)
Condenser
Dryer
Capillary tube
2-Way valve
(Flare connection)
Gas pipe (12.7 dia.)
(Flare connection)
(Flare connection)
Liquid pipe (6.35 dia.)
(Flare connection)
[ INDOOR UNIT ]
[ OUTDOOR UNIT ]
[ Connecting pipe ]
Evaporator
Com-
pressor
3-Way valve
(with charging port)
4-Way
valve
Condenser
Dryer
Capillary tube
for heating and cooling
Heating
Cooling
2-Way valve
Check
valve
Capillary tube heating
(Flare connection)
Gas pipe (12.7 dia.)
(Flare connection)
(Flare connection)
Liquid pipe (6.35 dia.)
(Flare connection)
[ INDOOR UNIT ]
[ OUTDOOR UNIT ]
[ Connecting pipe ]
Evaporator
Com-
pressor
REFRIGERANT SYSTEM DIAGRAM
Models : ASY14FSACW / AOY14FSAC
Models : ASY14USACW / AOY14USAC