¢ Ceiling type
• Rotation number range of compressor
Unit: rps
Connected model name Minimum rotation number Maximum rotation number
AOYG24KBTA3 10 130
• Limit of maximum speed based on outdoor temperature
A zone
26°C
B zone
C zone
D zone
23°C
20°C
Unit: rps
– Model: AOYG24KBTA3
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ABYG18KRTA
A zone 111 74 63 46
B zone 120 87 74 54
C zone 130 111 94 80
D zone 130 130 130 130