¢ Ceiling type
Each time the button is pressed, the air direction range will change as below:
• Remote controller display is not changed.
• Vertical airflow direction is set automatically as shown, in accordance with the type of operation
selected.
Cooling/dry mode : Horizontal flow 1
Heating mode : Downward flow 7
• During AUTO operation, for the first a few minutes after beginning operation, airflow will be hori-
zontal 1; the air direction cannot be adjusted during this period.
The airflow direction setting will temporarily become 1 when the temperature of the airflow is low at
the start of the Heating mode.
• After beginning of AUTO/HEAT mode operated and automatic defrosting operation, the airflow will
be horizontal 1. However, the airflow direction cannot be adjusted at beginning AUTO operation
mode.
¢ Floor type
Each time the button is pressed, the air direction range will change as below:
• Remote controller display is not changed.
• Vertical airflow direction is set automatically as shown, in accordance with the type of operation
selected.
Cooling/dry mode
: Horizontal flow 1
Heating mode : Downward flow 4
• During AUTO operation, for the first a few minutes after beginning operation, airflow will be hori-
zontal 1; the air direction cannot be adjusted during this period.
The airflow direction setting will temporarily become 1 when the temperature of the airflow is low at
the start of the Heating mode.
• After beginning of AUTO/HEAT mode operated and automatic defrosting operation, the airflow will
be horizontal 1. However, the airflow direction cannot be adjusted at beginning AUTO operation
mode.
4-1. Horizontal louver control
- (04-55) - 4. Louver control