EasyManua.ls Logo

Fujitsu AOYG36KQTA - Reactor Assy

Fujitsu AOYG36KQTA
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-8. Reactor assy
¢ Outdoor unit
Models: AOYG36KQTA, AOYG45KQTA, and AOYG54KQTA
Check point 1. Appearance check
No fissures, breaks, damage, etc. at the body and winding section, terminals section?
Check point 2. Electric check
1 Set the tester to the "Resistance" mode, and check for open/short between both ends of the re-
actor wire (or connector).
2 Judge the result of 1 as follows:
Short Normal
Open Abnormal (open)
*Reference value of DC resistance of reactor 0.132Ω Max (at 25°C)
4-8. Reactor assy - (03-61) - 4. Service parts information