Questions and Answers

  • H
    huntersmithSep 3, 2025
    What does serial reverse transfer error during the operation mean for Fujitsu Air Conditioner?
    • D
      David CardenasSep 3, 2025
      If your Fujitsu Air Conditioner displays a serial reverse transfer error during operation, it means the indoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • P
    Penny MedinaSep 18, 2025
    Why Fujitsu Air Conditioner has power supply frequency detection error?
    • D
      Douglas TurnerSep 18, 2025
      If your Fujitsu Air Conditioner displays a power supply frequency detection error, it means the power supply frequency cannot be recognized after 4 seconds of power ON. The Controller PCB might be defective.
  • K
    Kerri FreemanSep 16, 2025
    What does forced auto switch error mean on Fujitsu Air Conditioner?
    • D
      David MoralesSep 16, 2025
      If your Fujitsu Air Conditioner displays a forced auto switch error, it means the forced auto switch has been ON for 30 consecutive seconds. Check if the forced auto switch is kept pressed. The forced auto switch might be defective or the Controller PCB might be defective.
  • B
    Brandi HarmonSep 14, 2025
    What to do if my Fujitsu AOYS09LDC shows outdoor temperature thermistor error?
    • G
      Gene PetersonSep 14, 2025
      If your Fujitsu Air Conditioner displays an outdoor temperature thermistor error, it means the detection value of the outdoor temperature thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • J
    Justin StephensSep 12, 2025
    What does outdoor heat exchanger thermistor error mean for Fujitsu AOYS09LDC?
    • L
      Lori MccarthySep 13, 2025
      If your Fujitsu Air Conditioner displays an outdoor heat exchanger thermistor error, it means the detection value of the outdoor heat exchanger thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • K
    Kelly ThompsonSep 12, 2025
    What to do if my Fujitsu AOYS09LDC Air Conditioner shows discharge thermistor error?
    • E
      Eric BurnsSep 12, 2025
      If your Fujitsu Air Conditioner displays a discharge thermistor error, it means the detection value of the discharge thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • D
    David PowellSep 9, 2025
    What causes Indoor heat exchanger thermistor error in Fujitsu AOYS09LDC Air Conditioner?
    • C
      Crystal RoseSep 9, 2025
      If your Fujitsu Air Conditioner shows an indoor heat exchanger thermistor error, it means the detection value of the indoor heat exchanger thermistor is either open or shorted when the power is ON. Check the thermistor resistance value. The controller PCB might be defective.
  • C
    Crystal KimSep 7, 2025
    What does serial forward transfer error during the operation mean for Fujitsu AOYS09LDC?
    • N
      Nicole LongSep 7, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error during operation, it means the outdoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • A
    Alexandra MurraySep 5, 2025
    Why Fujitsu AOYS09LDC shows serial forward transfer error at starting up operation?
    • D
      Denise MeyerSep 5, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error at startup, it means the outdoor unit isn't receiving a signal for 10 seconds after the power relay turns on. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • U
    uschwartzAug 20, 2025
    Why my Fujitsu Air Conditioner does not operate at all?
    • A
      Amanda StephensAug 21, 2025
      If your Fujitsu Air Conditioner isn't operating, and the Operation Lamp and Timer Lamp aren't lit, you should check a few things: * Ensure the input power voltage from the exclusive circuit AC outlet is normal. * Make sure the AC plug is securely inserted into the AC outlet and isn't loose. * Verify that any connected cables are wired correctly. * Confirm that each connector is securely inserted.

Summary

Specifications

Model and Electrical Specifications

Details model types, electrical data, and compressor specifications.

Dimensions

ASYA07;09 LCC & AOYR07;09 LCC Dimensions

Diagrams showing dimensions for specific indoor and outdoor unit models.

ASYA12 LCC & AOYR12 LCC Dimensions

Diagrams detailing dimensions for ASYA12LCC and AOYR12LCC units.

Refrigerant System Diagram

Diagram for ASYA07;09 LCC & AOYR07;09 LCC

Illustrates the refrigerant flow for specified indoor/outdoor unit models.

Diagram for ASYA12 LCC, ASYB09;12 LDC & AOYS09;12 LDC

Shows the refrigerant system for multiple model series.

Diagram for ASYA14;18 LCC & AOYR14;18 LCC

Depicts the refrigerant circuit for larger capacity models.

Circuit Diagram

Wiring Diagram for ASYA07;09 LCC & AOYR07;09 LCC

Electrical schematic for specified indoor and outdoor unit models.

Wiring Diagram for ASYA12 LCC & AOYR12 LCC

Electrical circuit layout for ASYA12LCC and AOYR12LCC units.

Wiring Diagram for ASYB09;12 LDC & AOYS09;12 LDC

Electrical circuit diagram for ASYB/AOYS09/12LDC models.

Wiring Diagram for ASYA14;18 LCC & AOYR14;18 LCC

Electrical schematic for ASYA14/18LCC and AOYR14/18LCC units.

Description of Each Control Operation

Various Protections

Details on discharge gas temp, current release, and pressure protections.

Trouble Shooting

Unit Does Not Operate

Steps for diagnosing when the unit fails to start.

Installation Manual

General Precautions and Requirements

Covers general installation rules, accessories, electrical needs, and mounting position.

Fujitsu AOYS09LDC Specifications

General IconGeneral
BrandFujitsu
ModelAOYS09LDC
CategoryAir Conditioner
LanguageEnglish

Related product manuals