SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
ASYA07LCC
ASYA09LCC
ASYA12LCC
ASYA14LCC
ASYA18LCC
ASYB09LDC
ASYB12LDC
AOYR07LCC
AOYR09LCC
AOYR12LCC
AOYR14LCC
AOYR18LCC
AOYS09LDC
AOYS12LDC
INVERTER
SERVICE
INSTRUCTION
R410A

Other manuals for Fujitsu AOYS12LDC

Questions and Answers

  • D
    Deborah GomezSep 4, 2025
    What does serial reverse transfer error during the operation mean for Fujitsu Air Conditioner?
    • K
      Karen TaylorSep 4, 2025
      If your Fujitsu Air Conditioner displays a serial reverse transfer error during operation, it means the indoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • N
    Nancy LangSep 18, 2025
    Why Fujitsu Air Conditioner has power supply frequency detection error?
    • C
      Charles RiceSep 18, 2025
      If your Fujitsu Air Conditioner displays a power supply frequency detection error, it means the power supply frequency cannot be recognized after 4 seconds of power ON. The Controller PCB might be defective.
  • M
    Marie NielsenSep 16, 2025
    What does forced auto switch error mean on Fujitsu AOYS12LDC?
    • T
      Thomas AtkinsonSep 16, 2025
      If your Fujitsu Air Conditioner displays a forced auto switch error, it means the forced auto switch has been ON for 30 consecutive seconds. Check if the forced auto switch is kept pressed. The forced auto switch might be defective or the Controller PCB might be defective.
  • T
    Tony WhitakerSep 14, 2025
    What to do if my Fujitsu Air Conditioner shows outdoor temperature thermistor error?
    • M
      Michael DukeSep 14, 2025
      If your Fujitsu Air Conditioner displays an outdoor temperature thermistor error, it means the detection value of the outdoor temperature thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • P
    Paula RiveraSep 12, 2025
    What does outdoor heat exchanger thermistor error mean for Fujitsu Air Conditioner?
    • J
      John CookSep 13, 2025
      If your Fujitsu Air Conditioner displays an outdoor heat exchanger thermistor error, it means the detection value of the outdoor heat exchanger thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • R
    rebeccafletcherSep 12, 2025
    What to do if my Fujitsu AOYS12LDC Air Conditioner shows discharge thermistor error?
    • M
      Michael PettySep 12, 2025
      If your Fujitsu Air Conditioner displays a discharge thermistor error, it means the detection value of the discharge thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • M
    Mrs. Mary SimmonsSep 9, 2025
    What causes Indoor heat exchanger thermistor error in Fujitsu AOYS12LDC?
    • M
      Matthew SmithSep 9, 2025
      If your Fujitsu Air Conditioner shows an indoor heat exchanger thermistor error, it means the detection value of the indoor heat exchanger thermistor is either open or shorted when the power is ON. Check the thermistor resistance value. The controller PCB might be defective.
  • D
    Dr. Michelle HillSep 7, 2025
    What does serial forward transfer error during the operation mean for Fujitsu Air Conditioner?
    • J
      Joseph JonesSep 7, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error during operation, it means the outdoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • R
    Robert CarterSep 6, 2025
    Why Fujitsu AOYS12LDC Air Conditioner shows serial forward transfer error at starting up operation?
    • L
      leemichaelSep 6, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error at startup, it means the outdoor unit isn't receiving a signal for 10 seconds after the power relay turns on. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • H
    Hannah MoodyAug 21, 2025
    Why my Fujitsu AOYS12LDC Air Conditioner does not operate at all?
    • A
      Alec SheaAug 21, 2025
      If your Fujitsu Air Conditioner isn't operating, and the Operation Lamp and Timer Lamp aren't lit, you should check a few things: * Ensure the input power voltage from the exclusive circuit AC outlet is normal. * Make sure the AC plug is securely inserted into the AC outlet and isn't loose. * Verify that any connected cables are wired correctly. * Confirm that each connector is securely inserted.

Summary

1. SPECIFICATION

6. REFRIGERANT CAUTION -R410 A-

7. TROUBLE SHOOTING

Does not operate at all (Operation Lamp and Timer Lamp do not light up)

Troubleshooting steps for units that do not operate at all.

SELF-DIAGNOSIS FUNCTION

Explains the self-diagnosis function and memory reading.

Serial Signal Receiving Error

Troubleshooting steps for serial signal receiving errors between units.

IPM Protection

Checks and causes for IPM protection errors in the outdoor unit.

Trouble Shooting of Refrigerant Cycle

Diagnosis table and methods for refrigerant cycle issues.

8. APPENDING DATA

JP (Jumper) Setting

Explains indoor and outdoor unit jumper settings for custom codes and auto restart.

Outdoor Unit Low Pressure Value and Outdoor Total Electric Current Curve (Cooling)

Presents cooling performance curves for low pressure and current.

Outdoor Unit High Pressure Value and Outdoor Total Electric Current Curve (Heating)

Presents heating performance curves for high pressure and current.

Thermistor resistance values

Lists resistance values for various thermistors at different temperatures.

Room temperature thermistor

Resistance values for room temperature thermistors.

Indoor heat exchanger thermistor

Resistance values for indoor heat exchanger thermistors.

Discharge thermistor

Resistance values for discharge thermistors.

Outdoor heat exchanger thermistor

Resistance values for outdoor heat exchanger thermistors.

Outdoor temperature thermistor

Resistance values for outdoor temperature thermistors.

ASYA09 LCC Capacity;Input data (1;2)

Cooling and heating capacity/input graphs for ASYA09LCC.

ASYA12 LCC Capacity;Input data (1;2)

Cooling and heating capacity/input graphs for ASYA12LCC.

ASYA18 LCC Capacity;Input data (1;2)

Cooling and heating capacity/input graphs for ASYA18LCC.

ASYB09 LDC Capacity;Input data (1;2)

Cooling and heating capacity/input graphs for ASYB09LDC.

ASYB12 LDC Capacity;Input data (1;2)

Cooling and heating capacity/input graphs for ASYB12LDC.

9. REPLACEMENT PARTS

PROCESS Wiring lead wire

Instructions for wiring lead wires for the inverter assembly.

Process Connection of leads to inverter assy

Shows how to connect leads to the inverter assembly.

Process Shaping of leads to inverter assy

Illustrates shaping of leads for the inverter assembly.

PROCESS ATTACHMENT OF INVERTER ASSY

Details the process of attaching the inverter assembly.

PROCESS The leads are connected with INVERTER ASSY

Shows how leads are connected to the inverter assembly with labels.

PROCESS Fixing of Thermistor lead and motor lead.

Illustrates fixing of thermistor and motor leads.

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL

STANDARD ACCESSORIES

Lists standard installation accessories supplied with the product.

ELECTRICAL REQUIREMENT

Specifies requirements for the air conditioner's power supply.

SELECTING THE MOUNTING POSITION

Provides guidelines for choosing indoor and outdoor unit mounting locations.

1. INDOOR UNIT

Guidelines for selecting the indoor unit mounting position.

2. OUTDOOR UNIT

Guidelines for selecting the outdoor unit mounting position.

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

Illustrates the installation layout of indoor and outdoor units.

FRONT PANEL REMOVAL AND INSTALLATION

Instructions for removing and installing the front panel and intake grille.

AIR CLEANING UNIT REMOVAL

Steps to remove the air cleaning unit from the indoor unit.

AIR CLEANING UNIT INSTALLATION

Steps to install the air cleaning unit into the indoor unit.

CUSTOMER GUIDANCE

Advice on explaining operation and maintenance to the customer.

PUMP DOWN OPERATION (FORCED COOLING OPERATION)

Procedure for recovering refrigerant before unit relocation or disposal.

FINISHING

Instructions for insulating pipes and sealing gaps.

INDOOR UNIT

Specific installation steps for the indoor unit.

CUTTING THE HOLE IN THE WALL FOR THE CONNECTING PIPING

Details on cutting the wall hole for piping.

INSTALLING THE WALL HOOK BRACKET

Guidelines for securely installing the wall hook bracket.

FORMING THE DRAIN HOSE AND PIPE

Instructions for forming and routing the drain hose and piping.

INDOOR UNIT WIRING

Steps for connecting the indoor unit wiring.

OUTDOOR UNIT

Specific installation steps for the outdoor unit.

OUTDOOR UNIT INSTALLATION

General installation guidelines for the outdoor unit.

AIR PURGE

Procedure for purging air from the refrigerant circuit.

OUTDOOR UNIT WIRING

Steps for connecting the outdoor unit wiring.

CONNECTION

General connection steps for piping.

FLARING

Instructions for flaring refrigerant pipes.

CONNECTING THE PIPING

Steps for connecting the refrigerant piping.

TEST RUNNING

Procedures for performing test operation after installation.

Fujitsu AOYS12LDC Specifications

General IconGeneral
TypeSplit System
Cooling Capacity3.4 kW
Heating Capacity4.0 kW
RefrigerantR410A
Noise Level (Outdoor)50 dB(A)
Power Supply220-240V, 50Hz
Indoor Unit Weight9 kg