Loading...
1-4. Rotation number of compressor at normal start-up
¢ Models: AOHG30KBTA4 and AOHG36KBTA5
Rotation number of the compressor soon after starting is controlled as below.
Rotation number I
Rotation number II
Rotation number III
Rotation number IV
Rotation number V
Rotation number VI
Time 1
Time 2 Time 3
Time 4
Time 5
Time 6
Rotation number
(rps)
I II III IV V VI
35 52 64 71 89 97
Time (sec)
1 2 3 4 5 6
60 140 170 200 350 410