EasyManua.ls Logo

Fujitsu ARXG14KSLAP - Page 287

Fujitsu ARXG14KSLAP
403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heating mode
F zone
16°C
E zone
12°C
D zone
5°C
C zone
B zone
A zone
-1°C
-6°C
G zone
24°C
Unit: rps
Model name Outdoor temperature zone
Limitation of compressor
rotation number
AOHG14KBTA2
A zone 40
B zone 35
C zone 26
D zone 18
E zone 1
F zone 1
G zone 1
AOHG18KBTA2
A zone 30
B zone 25
C zone 15
D zone 15
E zone 15
F zone 10
G zone 1
1-5. Rotation number of compressor limitation by outdoor temperature - (04-25) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu ARXG14KSLAP

Related product manuals