7-8. High temperature and high pressure release control
The compressor is controlled as follows.
¢ Models: AOYG30KBTB, AOYG36KBTB, and AOYG45KBTB
Indoor unit heat exchanger
temperature rises
Indoor unit heat exchanger
temperature drops
Stable zone
AB
BC
CD
DE
Zone A
Zone B
Zone C
Zone D
Zone E
AB: 63°C
BC: 55°C
CD: 53°C
DE: 50°C
Zone Operation
Zone A Compressor is stopped.
Zone B
The compressor frequency is decreased.
-15 rps/120 sec.
Zone C -2 rps/120 sec.
Zone D
The protection is released and the operation is returned to normal mode.
Zone E
7-8. High temperature and high pressure release control - (01-33) - 7. Various protections
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS