EasyManua.ls Logo

Fujitsu ARXG-KHTAP Series User Manual

Fujitsu ARXG-KHTAP Series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
En-1
EnglishDeutschFrançaisEspañolItalianoPortuguês EλληvIkάРусскийTürkçe
NOTE: This manual describes how to install the air conditioner described above. Handling
and installation shall only be done by professionals as outlined in this manual.
1. SAFETY PRECAUTIONS
Be sure to read this manual thoroughly before installation.
The warnings and precautions indicated in this manual contain important information
pertaining to your safety. Be sure to observe them.
Hand this manual, together with the operating manual, to the customer. Request the
customer to keep them on hand for future use, such as for relocating or repairing the
unit.
WARNING
Indicates a potentially or imminently hazardous situation
which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation that may result in
minor or moderate injury or damage to property.
WARNING
The appliance shall be installed, operated and stored in a room with a oor area larger
than X m².
Amount of refrigerant charge
M (kg)
Minimum room area
X (m
2
)
M 1.22 -
1.22 < M 1.23 1.45
1.23 < M 1.50 2.15
1.50 < M 1.75 2.92
1.75 < M 2.0 3.82
2.0 < M 2.5 5.96
2.5 < M 3.0 8.59
3.0 < M 3.5 11.68
3.5 < M 4.0 15.26
(IEC 60335-2-40)
Installation of this product must be done by experienced service technicians or profes-
sional installers only in accordance with this manual. Installation by non-professional
or improper installation of the product might cause serious accidents such as injury,
water leakage, electric shock, or re. If the product is installed in disregard of the
instructions in this manual, it will void the manufacturer’s warranty.
Do not turn on the power until all work has been completed. Turning on the power be-
fore the work is completed can cause serious accidents such as electric shock or re.
If refrigerant leaks when you are working, ventilate the area. If the leaking refrigerant
is exposed to a direct ame, it may produce a toxic gas.
Installation must be performed in accordance with regulations, codes, or standards for
electrical wiring and equipment in each country, region, or the installation place.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they
do not play with the appliance.
To avoid danger of suffocation, keep the plastic bag or thin lm used as the packaging
material away from young children.
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open ames, an operating gas appliance or an operating
electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
AIR CONDITIONER
INDOOR UNIT (Duct type)
INSTALLATION MANUAL
PART No. 9381386215
[Original instructions] For authorized service personnel only.
Contents
1. SAFETY PRECAUTIONS ……………………………………………… 1
2. PRODUCT SPECIFICATION …………………………………………… 4
2.1. Installation tools ……………………………………………………4
2.2. Accessories …………………………………………………………4
2.3. Pipe requirement …………………………………………………… 5
2.4. Electrical requirement ……………………………………………… 5
2.5. Optional parts ……………………………………………………… 5
3. INSTALLATION WORK ………………………………………………… 5
3.1. Selecting an installation location ………………………………… 5
3.2. Installation dimension ……………………………………………… 6
3.3. Installing the unit …………………………………………………… 6
3.4. Intake duct connection …………………………………………… 7
3.5. Drain installation …………………………………………………… 7
3.6. Pipe installation …………………………………………………… 8
3.7. Fresh air intake ……………………………………………………… 9
3.8. Electrical wiring ………………………………………………… 10
3.9. Remote controller installation …………………………………… 11
4. OPTIONAL INSTALLATION WORK ………………………………… 11
4.1. Optional kit installation ………………………………………… 11
4.2. External input and output ……………………………………… 11
4.3. Remote sensor ………………………………………………… 12
5. REMOTE CONTROL INSTALLATION ……………………………… 12
5.1. Group control …………………………………………………… 12
5.2. Multiple remote control ………………………………………… 13
5.3. DIP switch 101 setting …………………………………………… 13
6. FUNCTION SETTING ………………………………………………… 13
6.1. Function details ………………………………………………… 13
6.2. Static pressure …………………………………………………… 14
7. CHECK LIST …………………………………………………………… 15
8. TEST RUN ……………………………………………………………… 15
8.1. Check items ……………………………………………………… 15
8.2. Operation method ……………………………………………… 15
9. FINISHING ……………………………………………………………… 15
10. CUSTOMER GUIDANCE ……………………………………………… 15
11. ERROR CODES ……………………………………………………… 16
9381386215-01_IM.indb 19381386215-01_IM.indb 1 12/5/2018 2:57:35 PM12/5/2018 2:57:35 PM
Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARXG-KHTAP Series and is the answer not in the manual?

Fujitsu ARXG-KHTAP Series Specifications

General IconGeneral
RefrigerantR32
Heating Capacity2.5 kW - 8.0 kW
Energy Efficiency Class CoolingA+++
Energy Efficiency Class HeatingA+++
Power Supply220-240V, 50Hz
Noise Level (Indoor Unit)19 dB - 45 dB

Summary

Safety Precautions

Precautions for using R32 refrigerant

Servicing

Service personnel

Information on authorized personnel for handling refrigerants and servicing.

Repairs to sealed components

Leak detection methods

Removal and evacuation

Charging procedures

Installation Work

Selecting an installation location

Guidelines for choosing a suitable installation location to avoid damage and ensure performance.

Pipe connection

Detailed steps for connecting refrigerant pipes, including flaring and tightening.

Pipe installation

Procedures for connecting refrigerant pipes, including warnings and precautions.

Drain installation

Guidelines for installing the drain hose and pipe for proper drainage.

Electrical wiring

Wiring system diagram

Diagram showing the electrical connections between indoor and outdoor units.

How to connect wiring to the terminals

Steps for connecting wires to terminal blocks using ring terminals.

Optional Installation Work

Remote Control Installation

Function Setting

Static pressure

Setting static pressure manually or automatically based on installation conditions.

Test Run

Check items

List of checks to perform after installation is complete.

Operation method

Procedures for performing test runs using different remote controllers.

Error Codes

Related product manuals