EasyManua.ls Logo

Fujitsu ARXG30KMLA - Page 81

Fujitsu ARXG30KMLA
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE PARTS INFORMATION 2
Check Point 1 : Check Connection
Check Point 2 : Check Winding Resistance
Check Point 3 : Replace Invereter PCB
U
V
W
Inverter Compressor
Check terminal connection of Compressor
(loose or incorrect wiring)
Check winding resistance of each terminal
If the resistance value is 0 or infinite, replace Compressor.
If the symptom does not change with above Check 1, 2, replace Inverter PCB.
02-44
Check Point 4 : Replace Main PCB
If the symptom does not change with above Check 1~3, replace Main PCB.
Resistance Value :
1.125 at 25°C (30/ 36 type)
0.766 at 20°C (45 type)
RED
WHITE
BLACK
Compressor
V(S)
U(R)
W400 W401 W402
(RED)
W(C)
(BLACK)
Terminal cover opened
(WHITE)
Inverter PCB

Other manuals for Fujitsu ARXG30KMLA

Related product manuals