4. Capacity table
Capacity tables show each of following values calculated based on the outdoor temperature and the
indoor temperature, under given Airflow Rate (AFR):
For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP)
For heating capacity: Total Capacity (TC) and Input Power (IP)
4-1. Cooling capacity
¢ ARXG45KHTA
AFR
m
3
/h
3,350
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-15 8.48 7.52 1.67 9.20 7.90 1.71 9.68 8.15 1.74 10.16 8.49 1.76 10.64 8.83 1.78 11.08 9.00 1.78 11.75 9.24 1.78
-10 8.56 7.56 1.70 9.29 7.94 1.74 9.77 8.19 1.76 10.26 8.53 1.79 10.74 8.88 1.81 11.19 9.04 1.81 11.86 9.29 1.81
0 8.73 7.63 1.75 9.47 8.02 1.79 9.96 8.27 1.82 10.46 8.62 1.84 10.95 8.96 1.87 11.41 9.13 1.87 12.09 9.38 1.87
5 8.57 7.56 1.80 9.30 7.94 1.84 9.78 8.19 1.86 10.27 8.54 1.89 10.76 8.88 1.92 11.20 9.05 1.92 11.88 9.29 1.92
10 8.42 7.49 1.84 9.13 7.87 1.88 9.61 8.12 1.91 10.08 8.46 1.94 10.56 8.80 1.96 11.00 8.96 1.96 11.66 9.21 1.96
15 8.27 7.37 1.89 8.98 7.74 1.94 9.45 7.99 1.96 9.91 8.32 1.99 10.38 8.66 2.02 10.82 8.82 2.02 11.47 9.05 2.02
20 11.05 9.41 3.54 11.99 9.88 3.62 12.61 10.20 3.67 13.24 10.62 3.72 13.86 11.05 3.78 14.44 11.25 3.78 15.31 11.56 3.78
25 10.58 9.17 3.66 11.48 9.63 3.74 12.08 9.94 3.80 12.68 10.36 3.85 13.28 10.77 3.90 13.83 10.97 3.90 14.66 11.27 3.90
30 10.11 8.94 3.78 10.97 9.39 3.86 11.54 9.68 3.92 12.12 10.09 3.98 12.69 10.49 4.03 13.22 10.69 4.03 14.01 10.98 4.03
35 9.64 8.70 3.90 10.46 9.14 3.99 11.01 9.43 4.04 11.55 9.82 4.10 12.10 10.22 4.16 12.61 10.40 4.16 13.36 10.69 4.16
40 8.22 7.68 3.51 8.92 8.06 3.59 9.38 8.32 3.64 9.85 8.67 3.70 10.32 9.02 3.75 10.75 9.18 3.75 11.39 9.43 3.75
46 6.51 6.45 3.05 7.07 6.78 3.12 7.44 6.99 3.16 7.80 7.28 3.21 8.17 7.58 3.25 8.51 7.72 3.25 9.03 7.93 3.25
¢ ARXG54KHTA
AFR
m
3
/h
3,350
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-15 9.58 8.34 1.89 10.39 8.76 1.93 10.94 9.04 1.96 11.48 9.42 1.99 12.02 9.80 2.02 12.52 9.98 2.02 13.28 10.25 2.02
-10 9.61 8.34 1.91 10.42 8.76 1.95 10.97 9.04 1.98 11.51 9.42 2.01 12.06 9.80 2.03 12.56 9.99 2.03 13.32 10.26 2.03
0 9.66 8.35 1.94 10.48 8.77 1.98 11.03 9.05 2.01 11.58 9.43 2.04 12.13 9.81 2.07 12.63 10.00 2.07 13.39 10.27 2.07
5 9.49 8.23 1.99 10.30 8.65 2.03 10.84 8.93 2.06 11.37 9.30 2.09 11.91 9.68 2.12 12.41 9.86 2.12 13.15 10.13 2.12
10 9.32 8.12 2.04 10.11 8.53 2.08 10.64 8.80 2.11 11.17 9.17 2.14 11.70 9.54 2.17 12.18 9.72 2.17 12.92 9.98 2.17
15 9.16 7.98 2.10 9.94 8.39 2.14 10.46 8.66 2.17 10.98 9.02 2.21 11.50 9.38 2.24 11.98 9.56 2.24 12.70 9.82 2.24
20 12.24 10.29 4.06 13.27 10.81 4.15 13.97 11.16 4.21 14.66 11.63 4.27 15.35 12.10 4.33 16.00 12.32 4.33 16.96 12.66 4.33
25 11.72 10.03 4.20 12.71 10.54 4.29 13.38 10.88 4.35 14.04 11.33 4.41 14.70 11.79 4.48 15.32 12.01 4.48 16.24 12.34 4.48
30 11.20 9.77 4.33 12.15 10.27 4.43 12.78 10.60 4.49 13.42 11.04 4.56 14.05 11.49 4.62 14.64 11.70 4.62 15.52 12.02 4.62
35 10.68 9.51 4.47 11.59 9.99 4.57 12.19 10.32 4.64 12.80 10.75 4.70 13.40 11.18 4.77 13.96 11.39 4.77 14.80 11.70 4.77
40 9.10 8.41 4.03 9.88 8.84 4.12 10.39 9.12 4.18 10.91 9.50 4.24 11.42 9.89 4.30 11.90 10.07 4.30 12.62 10.35 4.30
46 7.21 7.09 3.50 7.83 7.45 3.57 8.23 7.69 3.63 8.64 8.01 3.68 9.05 8.34 3.73 9.43 8.49 3.73 10.00 8.72 3.73
- 7 -
4-1. Cooling capacity 4. Capacity table
DUCT TYPE
ARXG45, 54KHTA
DUCT TYPE
ARXG45, 54KHTA

Table of Contents