2007.11.08
2
INDOOR UNIT
ARYA12LALU
OUTDOOR UNIT
AOYB12LACL
COMPRESSOR TYPE
Hermetic type, 4 poles, DC motor, Twin Rotary
DISCRIMINATION
WEIGHT (with oil)
DA130AIF-25NA
9.6 kg
STANDARD REFRIGERANT
REFRIGERANT TYPE
R410A R410A R410A
1,150 g
DIMENSIONS
Indoor unit
H x W x D Outdoor unit
WEIGHT Indoor unit
Gross / Net Outdoor unit
COMPRESSOR AND REFRIGERANT
MEASUREMENT
Pipe Length
15 m 1,150 g
FULL CHARGE
20 m 1,250 g
25 m 1,350 g
MAXIMUM PIPE HEIGHT 15 m
ADDITIONAL CHARGE
20 g/m
NOISE LEVEL
High speed 32 dB
INDOOR UNIT
Med speed 30 dB
Low speed
Quiet
Cooling
Heating
28 dB
26 dB
47 dB
48 dB
ARYA14LALU
AOYB14LACL
1,250 g
217 x 953 x 595 mm
578 x 790 x 300 mm
27 kg / 23 kg
44 kg / 40 kg
1,250 g
1,350 g
1,450 g
15 m
20 g/m
33 dB
31 dB
29 dB
27 dB
49 dB
49 dB
ARYA18LALU
AOYB18LACL
1,250 g
1,250 g
1,350 g
1,450 g
15 m
20 g/m
33 dB
31 dB
29 dB
27 dB
50 dB
50 dB
OUTDOOR UNIT
Note : Static pressure : 0Pa
Duct length : Inlet 1m, Outlet 2m (indoor uit)
When you dismantle indoor units which are installed,
take care not to make parts fall down, especially motors.