- 124 -
OUTDOOR UNIT
AOYG12-54LB
11. Safety devices
Type of
protection
Protection form
Model
AOYG12LBLA AOYG14LBLA
Circuit protection
Current fuse
(Filter PCB)
-
Current fuse
(Main PCB)
250 V, 15A
250 V, 3.15A
Current fuse
(Near the terminal)
250 V, 20A
250 V, 5A
Fan motor
protection
Thermal protection program
Activate
100+15/-10°C
Fan motor stop
Reset
95+15/-10°C
Fan motor restart
Compressor
protection
Terminal protection program
(Compressor temp.)
Activate
110°C
Compressor stop
Reset
After 40minutes and 80°C or less
Compressor restart
Thermal protection program
(Discharge temp.)
Activate
110°C
Compressor stop
Reset
After 7 minutes
Compressor restart
High pressure
protection
Pressure switch
Activate -
Reset -
Pressure sensor Heating
Activate -
Reset -
Thermal protection
program
(Heat exchanger
temp.)
Cooling
Activate
67°C
Compressor stop
Reset
After 3 minutes
Compressor restart
Low pressure
protection
Pressure sensor Cooling
Activate -
Reset -

Table of Contents

Other manuals for Fujitsu ARYG14LHTBP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARYG14LHTBP and is the answer not in the manual?

Fujitsu ARYG14LHTBP Specifications

General IconGeneral
BrandFujitsu
ModelARYG14LHTBP
CategoryAir Conditioner
LanguageEnglish

Related product manuals