SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Indoor unit Outdoor unit
INVERTER
AS*G07LMCA
AS*G09LMCA
AO*G07LMCA
AO*G09LMCA
AS*G12LMCA
AS*G14LMCA
AO*G12LMCA
AO*G14LMCA
ASYG07LMCE
ASYG09LMCE
AOYG07LMCE
AOYG09LMCE
ASYG12LMCE
ASYG14LMCE
AOYG12LMCE
AOYG14LMCE
ASYG07LMCE-R
ASYG09LMCE-R
AOYG07LMCE-R
AOYG09LMCE-R
ASYG12LMCE-R
ASYG14LMCE-R
AOYG12LMCE-R
AOYG14LMCE-R
Models
SERVICE
INSTRUCTION
R410A
RSG07LMCA
RSG09LMCA
ROG07LMCA
ROG09LMCA
RSG12LMCA
RSG14LMCA
ROG12LMCA
ROG14LMCA
Question and Answer IconNeed help?

Do you have a question about the Fujitsu AS G07LMCA Series and is the answer not in the manual?

Fujitsu AS G07LMCA Series Specifications

General IconGeneral
BrandFujitsu
ModelAS G07LMCA Series
CategoryAir Conditioner
LanguageEnglish

Summary

Description of Each Control Operation

Cooling Operation

Details on how the cooling mode operates based on temperature.

Heating Operation

Explains the heating mode operation and compressor frequency.

Dry Operation

Describes the compressor control and room temperature in dry mode.

Auto Changeover Operation

Flow chart for automatic switching between heating and cooling modes.

Indoor Fan Control

Explains indoor fan speed settings and airflow control in different modes.

Outdoor Fan Control

Details on outdoor fan motor type and speed control based on conditions.

Louver Control

Instructions for adjusting vertical and horizontal louvers for airflow direction.

Compressor Control

Covers compressor frequency ranges, start-up control, and temp limitations.

Timer Operation Control

Explains wireless remote controller timer functions like ON/OFF, Program, Sleep.

Electronic Expansion Valve Control

Details on the electronic expansion valve's pulse range and control.

Test Operation Control

Procedure for performing test operations for cooling and heating modes.

Prevent to Restart for 3 Minutes (3 Minutes ST)

Describes the 3-minute restart prevention for the compressor after stopping.

Four-Way Valve Extension Select

Explains the four-way valve switching process between cooling and heating.

Auto Restart

Function to automatically restart operation after a power failure.

Manual Auto Operation (Indoor unit body operation)

Operation without a remote control using the indoor unit's manual button.

Forced Cooling Operation (Test Operation)

Details on performing a forced cooling test operation.

Compressor Preheating

Describes the process of heating the compressor before operation.

10°C Heat Operation

Specific operation mode for heating at a minimum 10°C setting.

Economy Operation

Explains the energy-saving economy mode operation.

Outdoor Unit Low Noise Operation

Function to reduce noise from the outdoor unit during operation.

Powerful Operation

Describes the high-power mode for maximum performance.

Defrost Operation Control

Details on conditions for starting and completing defrost operation.

Off Defrost Operation Control

Explains the automatic defrost operation when heating is stopped.

Various Protections

Covers protection controls like discharge gas temp, current release.

Trouble Shooting

Error Display

Lists error codes and corresponding indoor unit display patterns.

Trouble Shooting With Error Code

Step-by-step troubleshooting for specific error codes like communication errors.

Trouble Shooting With No Error Code

Troubleshooting steps for issues like "Indoor Unit - No Power".

Service Parts Information

Information on diagnosing and replacing key components like the compressor.

Appending Data

Function Setting

Details on setting various indoor unit functions via remote control.

Thermistor Resistance Values

Tables of resistance values for various thermistors at different temperatures.