SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
INVERTER
SERVICE
INSTRUCTION
R410A
AS*G07LLCC
AS*G09LLCC
AS*G12LLCC
AO*G07LLCC
AO*G09LLCC
AO*G12LLCC
Question and Answer IconNeed help?

Do you have a question about the Fujitsu AS G09LLCC Series and is the answer not in the manual?

Fujitsu AS G09LLCC Series Specifications

General IconGeneral
BrandFujitsu
ModelAS G09LLCC Series
CategoryAir Conditioner
LanguageEnglish

Summary

1. DESCRIPTION OF EACH CONTROL OPERATION

1. COOLING OPERATION

Details how the compressor frequency is controlled based on room temperature for cooling.

2. HEATING OPERATION

Explains compressor frequency control based on room temperature during heating.

3. DRY OPERATION

Describes compressor frequency adjustment for dry mode based on detected room temperature.

4. AUTO CHANGEOVER OPERATION

Details automatic switching between heating, cooling, and dry modes based on temperature.

5. INDOOR FAN CONTROL

Explains fan speed settings and airflow control for the indoor unit in various modes.

6. OUTDOOR FAN CONTROL

Covers outdoor fan motor type and fan speed control based on zone and mode.

7. LOUVER CONTROL

Details vertical and right-left louver adjustments and swing operations.

8. COMPRESSOR CONTROL

Explains compressor frequency range, start-up control, and limitations by outdoor temperature.

9. TIMER OPERATION CONTROL

Describes ON/OFF, Program, and Sleep timer functions for the wireless remote controller.

10. TEST OPERATION CONTROL

Explains how to perform test operation and its conditions.

11. PREVENT TO RESTART FOR 3 MINUTES (3 MINUTES ST)

Details the 3-minute restart prevention for the compressor after stopping.

12. FOUR-WAY VALVE EXTENSION SELECT

Explains the timing of the four-way valve switch from cooling to heating mode.

13. AUTO RESTART

Covers automatic restart after a power interruption, memorizing previous settings.

14. MANUAL AUTO OPERATION (Indoor unit body operation)

Describes manual operation using the indoor unit's button when the remote is lost.

15. FORCED COOLING OPERATION (TEST OPERATION)

Explains forced cooling operation settings and conditions.

16. COMPRESSOR PREHEATING

Details the preheating process for the compressor when the outdoor heat exchanger is cold.

17. ECONOMY OPERATION

Explains the ECONOMY operation mode, which reduces output to about 70%.

18. POWERFUL OPERATION

Describes the POWERFUL operation mode for maximum power output.

19. DEFROST OPERATION CONTROL

Covers the conditions for starting and completing defrost operations.

20. OFF DEFROST OPERATION CONTROL

Details the automatic defrost operation when operation stops in heating mode.

21. VARIOUS PROTECTIONS

Explains protections like discharge gas temperature and current release controls.

2. TROUBLE SHOOTING

2-1 ERROR DISPLAY

Lists error codes and corresponding flashing patterns of indoor unit lamps.

2-2 TROUBLE SHOOTING WITH ERROR CODE

Provides troubleshooting steps for specific error codes, starting with serial communication errors.

2-3 TROUBLE SHOOTING WITH NO ERROR CODE

Offers troubleshooting for issues like 'Indoor Unit - No Power' without error codes.

2-4 SERVICE PARTS INFORMATION

Provides information on service parts and troubleshooting for components like the compressor.

3. APPENDING DATA

3-1 FUNCTION SETTING

Details on setting various functions for the indoor unit, including filter signs and temperature corrections.

3-2 Thermistor Resistance Values

Provides resistance and voltage values for indoor and outdoor unit thermistors at various temperatures.