EasyManua.ls Logo

Fujitsu ASU18CL

Fujitsu ASU18CL
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
ASU9RLQ
ASU12RLQ
ASU18CL
ASU18RL
AOU9RLQ
AOU12RLQ
AOU18CL
AOU18RL
INVERTER
SERVICE
INSTRUCTION
R410A

Table of Contents

Other manuals for Fujitsu ASU18CL

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASU18CL and is the answer not in the manual?

Fujitsu ASU18CL Specifications

General IconGeneral
BrandFujitsu
ModelASU18CL
CategoryAir Conditioner
LanguageEnglish

Summary

Specifications

Dimensions

Refrigerant System Diagram

Circuit Diagram

Description of Each Control Operation

Cooling Capacity Control

Controls compressor frequency based on room temperature sensor and set temperature.

Heating Operation

Heating Capacity Control

Controls compressor frequency based on room temperature sensor and set temperature.

Dry Operation

Indoor Unit Control

Compressor rotation frequency changes based on temp, set temp, and room temp variation.

Compressor Control

Operation Frequency Range

Details compressor operation frequency ranges for Cooling, Heating, and Dry modes.

Operation Frequency Control at Start Up

Illustrates the compressor frequency control sequence immediately after startup.

Electronic Expansion Valve Control

Test Operation Control

Defrost Operation Control

Off Defrost Operation Control

Various Protections

Discharge Gas Temperature Overrise Prevension Control

Controls compressor frequency to prevent discharge gas temperature from exceeding limits.

Current Release Control

Manages compressor frequency to prevent outdoor unit input current from exceeding limits.

Refrigerant Caution -R410 A-

R410 A Tools

Precaution for Installation

Precaution for Servicing

New Refrigerant R410 A

Defference from Conventional Model (R22) and Precautions

Trouble Shooting

When the unit does not operate at all

Troubleshooting steps and checks for when the unit fails to operate and lamps are off.

Self-diagnosis function and Checking points

Guide to interpreting self-diagnosis lamp displays and checking points for error codes.

Serial Signal Receiving Error

Troubleshooting guide for serial communication errors between indoor and outdoor units.

IPM Protection Troubleshooting

Steps to diagnose and resolve IPM protection errors in the outdoor unit.

Trouble Shooting of Refrigerant Cycle

Diagnosis table and methods for identifying and resolving refrigerant cycle issues.

Replacement Parts

Installation Manual

Preparation and Precautions

Important steps and warnings to follow before starting the installation process.

Electrical Requirements and Wiring

Details on electrical specifications, wiring diagrams, and connection procedures.

Indoor Unit Electrical Wiring

Instructions for wiring the indoor unit, including inter-unit harness and terminal connections.

Test Running and Power

Procedures for test running the unit and important power supply considerations.