JP (Jumper) Setting
[Indoor Unit]
ASU9/12RLQ
ASU18CL/RL
- Remote control custom code
When multiple number of indoor units are installed in the same room, erroneous receipt of the signal can
be avoided by setting up the remote control custom code separately.
To set up the remote control custom code, always set up the same code on both indoor unit PCB and
remote control PCB.
(When the indoor unit PCB is changed to Code B, it can not receive the signal unless remote control PCB
is also changed to Code B.)
Indoor Unit Remote Control
JM3(JP)
J4 (JP)
Code A (Default) YES YES
Code B NO NO
- Auto Restart
It is possible to disengage Auto Restart function if it is not needed.
Indoor Unit
JM2 (JP)
With Auto Restart function
(Default)
YES
Without Auto Restart
function
NO
[Outdoor Unit]
AOU9/12RLQ, AOU18CL/RL
JP
JM500
Normal Preheat YES
Higher Preheat NO
- it is possible to select the higher or standard level of preheating function.
- When it is set up at the higher level of preheat, the magnetic noise of the compressor becomes higher.
08-01