2-26. E: 65. IPM error (Outdoor unit)
Indicator Indoor unit
Operation indicator 6 time flash
Timer indicator 5 time flash
Economy indicator Continuous flash
Error code E: 65
Detective actuator Outdoor unit Main PCB
When the signal from FO terminal terminal of IPM is “L”
(0 V) during the compressor stopping.
Forecast of cause Main PCB failure
Check point 1. Replace the main PCB
Replace the main PCB.
End