State of indicator lamps
Lighting pattern: Off, On, Blinking, Any state
State Causes and solutions
See
page
Automatic defrosting operation
Please wait until nishing the defrosting
(maximum of 15 minutes).
9
Filter indicator
Clean the air lter and reset the lter
sign.
8
Error code display
Consult authorized service personnel.
-
Timer setting error because of Auto restart
Reset the clock and timer settings.
-
Test run operation (for authorized
personnel only)
Press
to quit the test run.
-
Restricted function
-
(Slow)
(Slow)
(In multi connection) Standby mode
Check the set operation mode of the
indoor units.
9
Manual Auto operation and Filter indicator
reset
You can operate the air conditioner with on the
indoor unit.
Status Time to keep pressing Mode or operation
In operation More than 3 seconds Stop
Stopping 2 seconds or less Filter indicator reset
More than 3 seconds and
less than 10 seconds
Auto *
1)
More than 10 seconds
(Only for servicing.*
2)
)
Forced cooling
*1) In multi connection, the operation mode follows the other indoor
units.
*2) To stop the forced cooling, press this button or
on the remote
controller.
(3 times)
(Fast)